Laserfiche WebLink
23. Bath House and Sanitary Wastewater: Is there a bath house at this facility? No M ❑ <br /> Are there sanitary wastewater facilities or sanitary treatment systems at this facility? No t_J Yes P9. <br /> If Yes to either question, what is the disposition of any wastewaters and sludge generated? <br /> Bathroom facilities in the office. Uses a leech field. <br /> 24. Ditches and Storm Sewers: Is any receiving water indicated in item 22 a ditch or storm sewer? _No ❑X Yes ❑ <br /> If Yes, submit documentation that the owner of the ditch or storm sewer allows this discharge. No hermit will be processed unless <br /> documentation of approval is received. <br /> 25. Certified Operator: Do you have a certified operator? No @ Yes ❑ If Yes, please list name(s), certification number(s) and <br /> level(s). For information regarding required certification, contact the Colorado Plant Operators Certification Board at(303)692-3500. <br /> 26. Discharge Quality: Analytical data for the parameters specified in the table beginning below and continuing on the next page, unless waived <br /> by the Division, shall be submitted for at least one grab sampling of each discharge point which is not solely made up of surface runoff or <br /> domestic wastewater as well as state waters upstream of each discharge. Upstream data should be from non-runoff periods,to the extent <br /> possible. Instream sampling is not required if upstream flow is intermittent or representative instream data exists on file. For new mines, <br /> please submit a minimum of one year data for those parameters listed below. Such data must have been obtained on at least a quarterly basis <br /> and must be reflective of the water quality prior to any mining activity. See instructions. If this is an application for renewal, reduced <br /> sampling may be appropriate,contact the Industrial Unit at(303) 692-3590. <br /> PARAMETER DETECTION PARAMETER DETECTION <br /> LEVEL VEL <br /> Total Dissolved Solids, mg/1 10 Total Recoverable Manganese,mg/1 0.05 <br /> Flow, MGD NA Dissolved Manganese,mg/1 0.05 <br /> pH, s.u. NA Total Mercury,mg/1 0.00025 <br /> 00 and Grease,mg/f 5 Total Recoverable Nickel, mg/l 0.05. <br /> Dissolved Oxygen, mg/1 NA Potentially Dissolved Nickel, mg/l 0.05 <br /> Alkalinity, mg/1 10 Total Recoverable Silver, mg/1 0.0002 <br /> Total Suspended Solids, mg/1 10 Potentially Dissolved Silver, mg/f 0.0002 <br /> Hardness,mg/f as CaCO3 10 Total Recoverable Uranium, mg/1 0.03 <br /> Total Ammonia, mg/1 0.05 Total Recoverable Zinc, mg/1 0.05 <br /> Temperature, °C-Winter NA Potentially Dissolved Zinc, mg/l 0.05 <br /> Temperature, °C -Summer NA Total Residual Chlorine, mg/1 0.05 <br /> Biochemical Oxygen Demand,mg/1 1 Fecal Coliform, No./100 ml NA <br /> Chemical Oxygen Demand, mg/1 30 Nitrate, mg/1 as N 0.1 <br /> Dissolved Aluminum, mg/1 0.1 Nitrite, mg/1 as N 0.002 <br /> Total Arsenic, mg/t 0.05 Sulfide mg/1 as H2S 0.1 <br /> Total Recoverable Cadmium, mg/l 0.0004 Boron, mg/1 0.05 <br /> Hexavalent Chromium,mg/1 0.025 Chloride, mg/1 5 <br /> Trivalent Chromium,mg/1 0.05 Sulfate, mg/1 5 <br /> Total Chromium,mg/1 0.005 Total Cyanide,mg/1 0.01 <br /> Total Recoverable Copper,mg/1 0.005 Total Recoverable Selenium, mg/1 0.002 <br /> Potentially Dissolved Copper,mg/1 0.005 Total Cobalt, mg/l 0.006 <br /> Total Recoverable Iron, mg/1 0.3 Gross Alpha, pCi/1 0.3 <br /> Dissolved Iron, mg/1 0.3 Total Radium 226 + 228,pCi/1 8 <br /> Total Recoverable Lead, mg/1 0.005 Total Fluoride, mg/t 0.1 <br /> Potentially Dissolved Lead, mg/1 0.005 Weak Acid Dissociable Cyanide,mg/1 0.01 <br /> Total Phenols, mg/1 0.100 Total Phosphorus,mg/1 as P 0.05 <br /> Total Organic Nitro en mg/1 as N 0.05 <br /> Coal Mining App.4/96 5 <br />