My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-08-21_HYDROLOGY - P2011003
DRMS
>
Day Forward
>
Hydrology
>
Prospect
>
P2011003
>
2012-08-21_HYDROLOGY - P2011003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:05:37 PM
Creation date
9/12/2012 12:27:28 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
P2011003
IBM Index Class Name
HYDROLOGY
Doc Date
8/21/2012
Doc Name
WQ SAMPLING RESULTS
From
KARMEN KING
To
DRMS
Email Name
RCO
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Dnve Steamboat Springs, CO 80487 (800) 334 -5493 <br />Re <br />11 Ott <br />Batch <br />Found <br />Limit <br />Lower <br />LCL <br />MDL <br />PCN /SCN <br />PQL <br />QC <br />Rec <br />RPD <br />Upper <br />UCL <br />Sample <br />A distinct set of samples analyzed at a specific time <br />Value of the QC Type of interest <br />Upper limit for RPD, in % <br />Lower Recovery Limit, in % (except for LCSS, mg /Kg) <br />Lower Control Limit <br />Method Detection Limit Same as Minimum Reporting Limit Allows for instrument and annual fluctuations <br />A number assigned to reagents /standards to trace to the manufacturer's certificate of analysis <br />Practical Quantitation Limit, typically 5 times the MDL <br />True Value of the Control Sample or the amount added to the Spike <br />Amount of the true value or spike added recovered, in % (except for LCSS, mg /Kg) <br />Relative Percent Difference, calculation used for Duplicate QC Types <br />Upper Recovery Limit, in % (except for LCSS, mg /Kg) <br />Upper Control Limit <br />Value of the Sample of interest <br />I le Ty <br />SURR <br />INTS <br />DUP <br />LCSS <br />LCSW <br />LFB <br />Blanks <br />Control Samples <br />Duplicates <br />Spikes/Fortified Matrix <br />B <br />E <br />H <br />J <br />L <br />M <br />P <br />R <br />T <br />U <br />V <br />X <br />Z <br />( <br />( <br />(3) <br />(4) <br />(5) <br />merits <br />(1) <br />( <br />(3) <br />REPINI 1 10 10 01 <br />Surrogate <br />Internal Standard <br />Sample Duplicate <br />Laboratory Control Sample - Soil <br />Laboratory Control Sample - Water <br />Laboratory Fortified Blank <br />LFM <br />LFMD <br />LRB <br />MS /MSD <br />PBS <br />PBW <br />0rgenic <br />Reference <br />Laboratory Fortified Matrix <br />Laboratory Fortified Matrix Duplicate <br />Laboratory Reagent Blank <br />Matrix Spike /Matrix Spike Duplicate <br />Prep Blank - Soil <br />Prep Blank - Water <br />QC.Sampler =Ty1 <br />Explanations <br />Verifies that there is no or minimal contamination in the prep method or calibration procedure <br />Verifies the accuracy of the method, including the prep procedure <br />Verifies the precision of the instrument and /or method <br />Determines sample matrix interferences, if any. <br />ACS <br />Analyte concentration detected at a value between MDL and PQL The associated value is an estimated quantity <br />Analyte concentration is estimated due to result exceeding calibration range <br />Analysis exceeded method hold time pH is a field test with an immediate hold time <br />Analyte concentration detected at a value between MDL and PQL The associated value is an estimated quantity <br />Target analyte response was below the laboratory defined negative threshold <br />Poor spike recovery is accepted because sample concentration is four times greater than spike concentration <br />Analyte concentration differs from second detector by more than 40% <br />Poor spike recovery accepted because the other spike in the set fell within the given limits <br />High Relative Percent Difference (RPD) accepted because sample concentrations are less than 10x the MDL <br />The material was analyzed for, but was not detected above the level of the associated value <br />The associated value is either the sample quantitation limit or the sample detection limit <br />High blank data accepted because sample concentration is 10 times higher than blank concentration <br />Quality control sample is out of control <br />Poor spike recovery is accepted because sample concentration is four times greater than spike concentration <br />EPA 600/4 -83 -020 Methods for Chemical Analysis of Water and Wastes, March 1983 <br />EPA 600/4- 90/020 Methods for the Determination of Organic Compounds in Drinking Water (I), July 1990 <br />EPA 600 /R- 92/129 Methods for the Determination of Organic Compounds in Drinking Water (II), July 1990 <br />EPA SW -846 Test Methods for Evaluating Solid Waste, Third Edition with Update III, December 1996 <br />Standard Methods for the Examination of Water and Wastewater, 19th edition, 1995 & 20th edition (1998) <br />QC results calculated from raw data. Results may vary slightly if the rounded values are used in the calculations <br />Soil, Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis <br />An asterisk in the "XQ" column indicates there is an extended qualifier and /or certification qualifier <br />associated with the result <br />For a complete list of ACZ's Extended Qualifiers, please click' http: / /wtvw acz com /puhlic!cxtquallist pdf <br />Page 25 of 54 <br />
The URL can be used to link to this page
Your browser does not support the video tag.