August 13, 2012 <br />Mr. Jim Stover <br />2352 North 7th St., Unit B <br />Grand Junction, CO 81501 <br />RE: BOWIE NO. 2 MINE (PERMIT NO. C- 1996 -083) <br />COAL MINE WASTE BANKS 1, 2 & 4 <br />2nd QUARTER 2012 INSPECTION REPORT REVIEW <br />SUB): RESPONSE TO DRMS COMMENTS, DATED JULY 30, 2012 <br />Dear Mr. Stover: <br />Civil, Structural & Geotechnical Engineers <br />222 South Park Ave. • Montrose, CO 81401 <br />Ph.: (970) 249 -6828 • FAX: (970) 249 -0945 <br />In response to the review letter from Mr. Brock Bowles of CDRMS, dated July 30, 2012, we offer <br />the following responses to the comments /questions. Our responses are in the same numeric <br />order as the comments in the referenced letter. <br />1. a. You are correct, Test #625 was erroneously reported as "not within spec." when an <br />adequate compaction of 90.1 percent was achieved. <br />b. Test #591 — Review of the laboratory correction calculations indicate that acceptable <br />rounding of moisture and specific gravity tests results in a percent compaction of <br />90.0 %. This differs from the reported value on the daily compaction record sheet <br />included in the report due to one significant figure reporting by the field technician. <br />The compaction density of 90.0% is correct and future reports will reflect the results of <br />two significant figure calculations derived in the laboratory. <br />c. Test #600 - Review of the laboratory correction calculations indicate that acceptable <br />rounding of moisture and specific gravity tests results in a percent compaction of <br />90.0 %. This differs from the reported value on the daily compaction record sheet <br />included in the report due to one significant figure reporting by the field technician. <br />The compaction density of 90.0% is correct and future reports will reflect the results of <br />two significant figure calculations derived in the laboratory. <br />d. Test #666 - Review of the laboratory correction calculations indicate that acceptable <br />rounding of moisture and specific gravity tests results in a percent compaction of <br />90.0 %. This differs from the reported value on the daily compaction record sheet <br />included in the report due to one significant figure reporting by the field technician. <br />The compaction density of 90.0% is correct and future reports will reflect the results of <br />two significant figure calculations derived in the laboratory. <br />e. Test #671 should have been marked as "not within spec. ", but due to a typographic <br />error it was not. The original handwritten field density sheet and the Daily Observation <br />Report both dated 6/25/12, note that Test #671 did not meet density compaction <br />requirement of 90 %. This test was re- tested as #671A and passed on 7/2/12 and will <br />be reported in the next quarterly report. <br />