Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Silver Star Resources, LLC ACZ Project ID: L92784 <br />ACZ 10 WORKNUM PARAMETER <br />METHOD <br />QUAL <br />DESCRIPTION <br />L92784-06 WG317347 Silver, dissolved <br />M200.8 ICP -MS <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />M200.8 ICP -MS <br />ZA <br />Poor recovery for Silver quality control is accepted due to <br />low Silver solubility in samples, digestates, or extracts that <br />do not contain sufficient Hydrochloric add. <br />WG317213 Chloride <br />SM4500CI -E <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />WG317290 Cyanide, total <br />M335.4 - Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG317287 Cyanide, WAD <br />SM4500 -CN I- Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MOL). <br />WG317248 Fluoride <br />SM4500F -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG317374 Nitrate/Nitrite as N <br />M353.2 - H2SO4 preserved <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL), <br />WG316982 Phosphorus, ortho dissolved <br />M365.1 - Automated Ascorbic <br />HE <br />Analysis performed past holding time. Method holding time <br />Add <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZs Terms & Conditions). <br />M365.1 - Automated Ascorbic <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />Add <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG317096 Residue, Non Filterable (TSS) @105C <br />SM2540D <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG317343 Sulfate <br />D516 -02 - Turbddimetric <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />L92784-07 WG317347 <br />WG317290 <br />WG317287 <br />WG317248 <br />WG317374 <br />WG316982 <br />Silver, dissolved <br />Cyanide, total <br />Cyanide, WAD <br />Fluoride <br />Nitrate/Nitrite as N <br />Phosphorus, ortho dissolved <br />M200.8 ICP -MS <br />M200.8 ICP -MS <br />M335.4 - Colodmetnc w/ <br />distillation <br />SM4500 -CN I- Colonmet6cw/ <br />distillation <br />SM4500F -C <br />M353.2 - H2SO4 preserved <br />M365.1 - Automated Ascorbic <br />Add <br />M365.1 - Automated Ascorbic <br />Add <br />WG317096 Residue, Non - Filterable (TSS) @105C SM2540D <br />WG317343 Sulfate D516 -02 - Turbidimetric <br />REPAD.15.06.05.01 <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />ZA Poor recovery for Silver quality control is accepted due to <br />low Silver solubility in samples, digestates, or extracts that <br />do not contain sufficient Hydrochloric add. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< IOx MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZs Terms & Conditions). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MOIL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />Page 31 of 37 <br />