Laserfiche WebLink
TABLE 1 <br /> SAMPLING LOCATIONS AND ANALYTICAL METHODS <br /> Sampling Location Conditions to be Sample Sample Analytical <br /> Assessed Type & Collection Constituents <br /> Number Method <br /> Main Plant Yard; About 120' NE of Ground-water quality; potential GW (3) Existing seeps, driven well, VOCs, PCBs, <br /> Maintenance Shop release of waste oil, diesel fuel, or drilled wells Inorganics, Metals <br /> and/or PCBs <br /> Main Plant Yard; About 35' north, Soil conditions; potential release of Soil (6) Three exploratory pits dug BTEX, TEPH, <br /> 20' east & 20' southeast of waste oil, diesel fuel, and/or PCBs with backhoe O&G, PCBs <br /> Maintenance Shop <br /> 001 Pond Discharge Quality of surface water discharging SW (1) Directly from discharge VOCs, Inorganics, <br /> from the site to Coal Creek stream Metals <br /> Haulage Tunnels Discharge Quality of the water discharging from SW (1) Directly from discharge Inorganics, Metals <br /> tunnels stream <br /> Rock Tunnel Waste Pile Quality of water discharging from SW (1) Collection of seepage Inorganics, Metals <br /> Rock Tunnel Waste Pile emerging from base of pile <br /> Old Refuge Pile Quality of water discharging from Old SW (1) Collecting seepage emerging VOCs, PCBs, <br /> Refuge Pile from the base of pile Inorganics, Metals <br /> Sutey Pile Underdrain Quality of the drainage from beneath SW(1) Directly from discharge VOCs, PCBs, <br /> the Sutey pile prior to discharge to stream Inorganics, Metals <br /> Coal Creek <br /> Sutey Pile- existing monitoring well Ground-water quality directly GW (1) Bailer or submersible pump VOCs, PCBs, <br /> GS-1 downgradient of the Sutey Pile Inorganics, Metals <br /> - 8 - <br />