Laserfiche WebLink
lambert anb 2,000ciates <br /> CONSULTING GEOTECHNICAL ENGINEERS AND MATERIAL TESTING <br /> August 22 , 1988 <br /> Sunnyside Gold Corporation <br /> p. O. Box 177 <br /> Silverton , CO 81433 <br /> PN : M88052MT <br /> Attention : Mike Foutz <br /> Subject : Permeability tests results for <br /> Two (2) Sampled Delivered to our Laboratory <br /> Mr. Foutz : <br /> This letter presents the results of permeability tests <br /> performed on two (2) jamples of material received in our <br /> laboratory on August 10 , 1988. As your requested our <br /> laboratory tests included performing standard moisture-density <br /> relationship tests , ASTM Test Method D698 , on each sample. <br /> The permeability tests were conducted in triaxial compressive <br /> strength tests chambers with a constant head. The permeability <br /> test samples were remolded to about 95 percent relative compaction <br /> at/or near optimum moisture content based on the moisture-density <br /> relationship test results . The results of the moisture-density <br /> tests and the permeability tests are attached. The test results <br /> were discussed with Mr. Larry- Perino on August 19 , - 1988. <br /> If you have any questions concerning the test results or if <br /> we may be of further assistance please contact us. <br /> Respectfully submitted, <br /> LAMBERT AND ASSOCIATES <br /> Norman W nston , P .E . <br /> attachments <br /> NWJ/nr <br /> P.O.BOX 3986 P.O.BOX 0045 463 TURNER,104 A <br /> GRAND JUNCTION,CO 81502 MONTROSE,CO 81402 DURANGO,CO 81301 <br /> (303)245-6506 (303)249-2154 (303)259-5095 <br />