Laserfiche WebLink
Table 6-1-2 <br /> Parameter, Procedure, and Reference List for Phase I and <br /> Phase II Sampling at the Proposed Nucla East Mine, <br /> Montrose County, Colorado <br /> March, 1988 <br /> Parameter-Units Procedure-Reference <br /> Sample preparation Samples were dried at less than 35°C and crushed <br /> to pass a 10 mesh sieve (excessive grinding was <br /> avoided). <br /> Subsampling less than 2 mm fraction USDA (1969), Method 1, p. 83-84. <br /> Preparation of saturation extract USDA (1969), Methods 2 and 3a, pp. 84 and 88, <br /> and saturation percentage and Method 27b, p. 107. <br /> determination <br /> pH (determination using saturated USDA (1969), Method 21a, p. 102. <br /> paste) <br /> Conductivity of saturation extract Sandoval and Power (1978), Method 1, pp. 22-24. <br /> in mmhos/cm at 25°C <br /> Calcium content in the saturation Sandoval and Power (1978), Method 2, p. 24-26. <br /> extract in meq/1 <br /> Magnesium content in the saturation Same as Calcium. <br /> extract in meq/1 <br /> Sodium content in the saturation Same as Calcium. <br /> extract in meq/1 <br /> SAR USDA (1969), p. 26. <br /> ESP in % (determined if SAR is Sandoval and Power (1978), Method 6A, p. 9. <br /> greater than 11) <br /> Sulfate content in the saturation Sandoval and Power (1978), Method 7A, p. 29-30. <br /> extract in meq/1 <br /> Total alkalinity in the saturation APHA (1980), Method 403, p. 253-257. <br /> extract in meq/1 <br /> Nitrate-Nitrogen in the saturation Page (1982), Section 10-3.6, p. 175. <br /> extract in ppm <br /> Ammonium-nitrogen (extractable) Black (1965), Extraction by 2N NaCl, p. <br /> in ppm 1185-1212. 60 mesh sieve. <br /> 6-1-24 Revised 04/11/88 <br />