My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1991-05-16_REVISION - C1981035 (2)
DRMS
>
Day Forward
>
Revision
>
Coal
>
C1981035
>
1991-05-16_REVISION - C1981035 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2021 5:17:53 AM
Creation date
4/16/2012 1:28:35 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981035
IBM Index Class Name
REVISION
Doc Date
5/16/1991
Doc Name
Hydrologic Design of East Drainage Channel and Sediment Ponds
From
Don May
To
DMG
Type & Sequence
TR2
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Emergency Spillway <br /> Type: Rectangular Sharp Crested Weir <br /> C = 3.27 <br /> L = 8ft <br /> Crest Elev. = 97.7 <br /> Max. Head = 0. 3 ft <br /> where C is the orifice discharge coefficient, A the area of the <br /> opening in ftZ, and Ho is the head on the orifice in feet, and Q is <br /> the discharge in cfs. The invert of the orifice is at elevation <br /> 87 . 17 and the maximum water surface during the 25yr event is 98. A <br /> standard discharge coefficient of 0.7 was used. <br /> The orifice discharges water into an 12 inch diameter pipe which <br /> terminates in the field west of the pond. In order to maintain <br /> inlet control at maximum discharge (= 1 cfs) , the outlet pipe must <br /> be at a minimum slope 0. 007 (0.7%) . Under these conditions, the <br /> pipe will be flowing nearly full. Any slope greater than this will <br /> shorten the length of pipe required and increase the discharge <br /> capacity (Simon, 1981) . <br /> The outlet works characteristics are summarized in the tables and <br /> shown in figures 2 and 3 . The discharge rating curve for the <br /> orifice can be seen in the HEC-1 run entitled 'Low-Level Outlet <br /> Performance' in the appendix 4 . The combined rating curve for the <br /> orifice and the weir is seen in the HEC-1 output entitled 'Design <br /> Storm, Full Pond and 25yr-24hr Event' , appendix 3 . <br /> 4 . West Sediment Pond <br /> Hydrology <br /> The 10yr-24hr and 25yr-24hr design events were computed and <br /> routed through the West Pond using the HEC-1 model (HEC, 1981) . The <br /> procedure is identical to that described in section 3 for the East <br /> Pond. The following table lists the watershed parameters <br /> for the 10yr and 25yr events <br /> Watershed Parameters for Westside Drainage <br /> Drainage Area = 43 .5 acres <br /> Length to Divide A� 2500 ft <br /> Curve Number = 72 <br /> Average Slope = 12.8% <br /> Lag Time = 12 . 6 minutes <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.