Laserfiche WebLink
Test <br />Normal <br />Measured Peak <br />Measured Residual <br />Reference <br />Series <br />Stress <br />Shear Strength <br />Shear Strength <br />Appendix <br />Number <br />(psi) <br />(psi) <br />(psi) . <br />Figure Number <br />1 <br />50 <br />35.5 <br />35.5 <br />1 -1 and 1 -2 <br />100 <br />68.5 <br />68.5 <br />150 <br />88.9 <br />88.9 <br />300 <br />170.0 <br />170.0 <br />Note: <br />0 , <br />TABLE 3 <br />INTERFACE DIRECT SHEAR TEST RESULTS <br />MEASURED PEAK AND RESIDUAL TOTAL SHEAR STRENGTHS <br />GOLDER ASSOCIATES, INC. <br />GOLDER PROJECT NUMBER 933- 2442.9 <br />For the 50. 100, and 150 psi tests. a 12 -in. by 12 -in. (300 - mm by 300 shear box was used <br />and the 300 psi test was conducted in a 6 -in. oy 6 -in. (150-mm by 150 -mm) shear box. Each test <br />specimen was sheared immediately after application of the normal stress. <br />;GL3458/GEL93234 93.09.29 <br />