My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-02-27_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2012-02-27_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:49:02 PM
Creation date
3/7/2012 7:10:54 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
2/27/2012
Doc Name
Fourth Quarter 2011 Groundwater Sampling
From
Golder Associates
To
DRMS
Permit Index Doc Type
Hydrology Report
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ADZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Spnngs, CO 80487 (800) 334 -5493 <br />Roill litmder Explanations <br />Batch <br />Found <br />Limit <br />Lower <br />MDL <br />PCN /SCN <br />PQL <br />QC <br />Rec <br />RPD <br />Upper <br />Sample <br />AS <br />ASD <br />CCB <br />CCV <br />DUP <br />ICB <br />ICV <br />ICSAB <br />LCSS <br />LCSSD <br />LCSW <br />A distinct set of samples analyzed at a specific time <br />Value of the QC Type of interest <br />Upper limit for RPD, in %. <br />Lower Recovery Limit, in % (except for LCSS, mg /Kg) <br />Method Detection Limit Same as Minimum Reporting Limit. Allows for instrument and annual fluctuations. <br />A number assigned to reagents /standards to trace to the manufacturer's certificate of analysis <br />Practical Quantitation Limit, typically 5 times the MDL. <br />True Value of the Control Sample or the amount added to the Spike <br />Amount of the true value or spike added recovered, in % (except for LCSS, mg /Kg) <br />Relative Percent Difference, calculation used for Duplicate QC Types <br />Upper Recovery Limit, in % (except for LCSS, mg /Kg) <br />Value of the Sample of interest <br />QC Sample Types <br />Analytical Spike (Post Digestion) <br />Analytical Spike (Post Digestion) Duplicate <br />Continuing Calibration Blank <br />Continuing Calibration Verification standard <br />Sample Duplicate <br />Initial Calibration Blank <br />Initial Calibration Verification standard <br />Inter - element Correction Standard - A plus B solutions <br />Laboratory Control Sample - Soil <br />Laboratory Control Sample - Soil Duplicate <br />Laboratory Control Sample - Water <br />LCSWD <br />LFB <br />LFM <br />LFMD <br />LRB <br />MS <br />MSD <br />PBS <br />PBW <br />PQV <br />SDL <br />Laboratory Control Sample - Water Duplicate <br />Laboratory Fortified Blank <br />Laboratory Fortified Matrix <br />Laboratory Fortified Matrix Duplicate <br />Laboratory Reagent Blank <br />Matrix Spike <br />Matrix Spike Duplicate <br />Prep Blank - Soil <br />Prep Blank - Water <br />Practical Quantitation Verification standard <br />Serial Dilution <br />Blanks <br />Control Samples <br />Duplicates <br />Spikes /Fortified Matrix <br />Standard <br />Verifies that there is no or minimal contamination in the prep method or calibration procedure <br />Verifies the accuracy of the method, including the prep procedure <br />Verifies the precision of the instrument and /or method <br />Determines sample matrix interferences, if any <br />Verifies the validity of the calibration <br />B Analyte concentration detected at a value between MDL and PQL. The associated value is an estimated quantity. <br />H Analysis exceeded method hold time pH is a field test with an immediate hold time <br />L Target analyte response was below the laboratory defined negative threshold <br />U The material was analyzed for, but was not detected above the level of the associated value. <br />The associated value is either the sample quantitation limit or the sample detection limit <br />(1) <br />(2) <br />(3) <br />(4) <br />(5) <br />(1) <br />( <br />(3) <br />(4) <br />REPIN11.10 10 01r <br />EPA 600/4 -83 -020 Methods for Chemical Analysis of Water and Wastes, March 1983 <br />EPA 600/R -93 -100. Methods for the Determination of Inorganic Substances in Environmental Samples, August 1993 <br />EPA 600/R -94 -111 Methods for the Determination of Metals in Environmental Samples - Supplement I, May 1994 <br />EPA SW -846 Test Methods for Evaluating Solid Waste, Third Edition with Update III, December 1996 <br />Standard Methods for the Examination of Water and Wastewater, 19th edition, 1995 & 20th edition (1998) <br />Comments <br />QC results calculated from raw data Results may vary slightly if the rounded values are used in the calculations. <br />Soil, Sludge, and Plant matrices for Inorganic analyses are reported on a dry weight basis <br />Animal matrices for Inorganic analyses are reported on an as received" basis <br />An asterisk in the "XQ" column indicates there is an extended qualifier and /or certification qualifier <br />associated with the result. <br />For a complete list of ACZ's Extended Qualifiers, please click http: '\ \\\ w.aei.com'public , extqualhst.pdf <br />Page 14 of 36 <br />
The URL can be used to link to this page
Your browser does not support the video tag.