Laserfiche WebLink
ENERGY <br />Client: Cotter Corporation <br />Project: Schwartz GW 12/30/11 S26173 <br />Analyte Count <br />Method: E900.0 <br />Sample ID: MB -GrAB -1228 <br />Gross Alpha <br />Gross Alpha precision ( ±) <br />Gross Alpha MDC <br />Gross Beta <br />Gross Beta precision ( ±) <br />Gross Beta MDC <br />Sample ID: Th230 -GrAB -1228 <br />Gross Alpha <br />- LCS response is outside of the acceptance <br />Sample ID: Cs137 -GrAB -1228 <br />Gross Beta <br />Gross Alpha <br />Gross Alpha precision ( ±) <br />Gross Alpha MDC <br />Gross Beta <br />Gross Beta precision ( ±) <br />Gross Beta MDC <br />Sample ID: 012010218 -001 FMSD <br />Gross Alpha <br />Sample ID: C12010218 -001 FMS <br />Gross Beta <br />Sample ID: C1 201 021 8 -001 FMSD <br />Gross Beta <br />www.energylab.wm <br />Aeaylical Excesses S1nc 1851 <br />Qualifiers: <br />RL - Analyte reporting limit. <br />MDC - Minimum detectable concentration <br />S - Spike recovery outside of advisory limits. <br />6 Method Blank <br />-1 <br />0.7 <br />1 <br />-0.7 <br />1 <br />2 <br />Sample ID: C12010032- 001ADUP 6 Sample Duplicate <br />-3.6 <br />2.1 <br />2.5 <br />-1.7 <br />1.9 <br />2.0 <br />QA/QC Summary Report <br />Prepared by Casper, WY Branch <br />Result Units <br />pCi /L <br />pCi /L <br />pCi /L <br />pCi /L <br />pCi/L <br />pCi /L <br />Laboratory Control Sample Run: G542M_120201 B <br />68.0 pCi /L 67 80 120 <br />range for this analysis. Since the MB, MS, and MSD are acceptable the batch is approved. <br />Laboratory Control Sample <br />165 pCi /L <br />pCi /L <br />pCi /L <br />pCi /L <br />pCi /L <br />pCi /L <br />pCi /L <br />Sample Matrix Spike <br />96.5 pCi /L <br />Sample Matrix Spike Duplicate <br />95.8 pCi /L <br />Sample Matrix Spike <br />152 pCi /L <br />Sample Matrix Spike Duplicate <br />161 pCi /L <br />Helena, MR 877472 -0711 • Billings, MT 801- 735 -4488 • Casper, WY 888 -235 -0515 <br />Gillette, WY 866- 686 -7175 • Rapid City, SD 886 -672 -1225 • College Station, TX 888 -680 -2218 <br />RL %REC Low Limit High Limit RPD RPDLimit Oual <br />Run: G542M_120201B <br />Run: G542M_120201B <br />96 80 120 <br />Run: G542M_120201B <br />Run G542M_120201B <br />101 70 130 <br />Run: G542M_120201B <br />94 70 130 <br />Run: G542M_120201B <br />91 70 130 <br />Run: G542M_120201B <br />95 70 130 <br />Report Date: 02/07/12 <br />Work Order: C12010004 <br />ND - Not detected at the reporting limit. <br />R - RPD exceeds advisory limit <br />U - Not detected at minimum detectable concentration <br />Batch GrAB -1228 <br />02/06/12 00:09 <br />U <br />U <br />02/06/12 00:09 <br />S <br />02/06/12 00:09 <br />02/06/12 0009 <br />32 144.5 U <br />1700 220.7 UR <br />- For Gross Beta the activity of original sample is at the detection limit, duplicate is below detection limit, but within the limits of precision, resulting in high RPD. Batch is <br />acceptable. <br />Sample ID: C12010218 -001 FMS <br />Gross Alpha <br />0.7 <br />Page 17 of 21 <br />02/07/12 12:19 <br />02/07/12 12:19 <br />17.9 <br />02/07/12 12:19 <br />02/07/12 12:19 <br />5.4 13.9 <br />