Laserfiche WebLink
Accutest Laboratories <br />Dissolved Metals Analysis <br />(1) Instrument QC Batch: MA1484 <br />(2) Instrument QC Batch: MA1487 <br />(3) Prep QC Batch: MP4494 <br />RL = Reporting Limit <br />Report of Analysis <br />Page 1 of 1 <br />Client Sample ID: MW -004 <br />Lab Sample ID: D22645 -3FA Date Sampled: 04/13/11 <br />Matrix: AQ - Water Filtered Date Received: 04/14/11 <br />Percent Solids: n/a <br />Project: GCC <br />Analyte Result RL Units DF Prep Analyzed By Method Prep Method <br />Antimony < 0.80 0.80 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />Arsenic <1.6 1.6 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />Cadmium <0.20 0.20 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />Copper 4.8 4.0 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />Lead <1.0 1.0 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />Selenium 57.3 0.80 ug /1 2 04/18/11 04/27/11 GJ EPA 200.8 2 EPA 200.8 3 <br />Silver < 0.20 0.20 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />Thallium < 0.40 0.40 ug /1 2 04/18/11 04/26/11 JM EPA 200.8 1 EPA 200.8 3 <br />N <br />3 <br />21 of 68 <br />