Laserfiche WebLink
Accutest Laboratories <br />Client Sample ID: MW -002 <br />Lab Sample ID: D22645 -1F <br />Matrix: AQ - Water Filtered <br />Project: GCC <br />Date Sampled: 04/13/11 <br />Date Received: 04/14/11 <br />Percent Solids: n/a <br />General Chemistry <br />Analyte <br />Alkalinity, Bicarbonate as CaC 743 <br />Alkalinity, Carbonate < 5.0 <br />Alkalinity, Total as CaCO3 <br />Cation Anion Balance a <br />Chloride <br />Hardness, Total as CaCO3 b <br />Nitrogen, Nitrate c <br />Nitrogen, Nitrite C <br />Sulfate <br />RL = Reporting Limit <br />Report of Analysis <br />Result RL Units DF Analyzed <br />5.0 mg /l 1 04/19/11 JD <br />5.0 mg /1 1 04/19/11 JD <br />743 5.0 mg /1 1 04/19/11 JD <br />17.9 % 1 04/20/11 MM <br />35.2 1.0 mg /1 2 04/14/11 11:44 JML <br />821 1.8 mg /1 1 04/18/11 14:19 GJ <br />< 0.090 0.090 mg /l 2 04/14/11 11:44 JML <br />< 0.12 0.12 mg /1 2 04/14/11 11:44 JML <br />862 25 mg /1 50 04/14/11 18:56 JML <br />By Method <br />(a) Poor balance due to alkalinity influence. Alkalinity is measured on a total basis, while other anions and <br />cations are measured on a dissolved basis. This sample had heavy sediment. <br />(b) Calculated as: (Calcium * 2.497) + (Magnesium * 4.118) <br />(c) Elevated detection limit due to matrix interference. <br />Page l of l <br />SM20 2320B <br />SM20 2320B <br />SM20 2320B <br />SM20 1030E <br />EPA 300/SW846 9056 <br />SM20 2340B <br />EPA 300/SW846 9056 <br />EPA 300/SW846 9056 <br />EPA 300 /SW846 9056 <br />■; 8 of 68 <br />• accuz <br />D22645 ° ° °° ° " "� <br />