Laserfiche WebLink
INSPECTOR'S NAME: Dennis Jones DATE: 1o_? - <br />NPDES I.D. NO.: CO- 0000221 D.P. 006 <br />FACILITY CONFIGURATION: Cross - Valley Pond <br />SITE NAME: Pond #006 <br />MINE NAME: Seneca II -W Mine (Seneca Coal Co) <br />MINE I.D. NO.: CMLRD Permit No. C -82 -057 <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />17. <br />18. <br />Foundation preparation (removal of vegetation, stumps, topsoil: <br />Lift thickness: <br />Compaction according to approved plan: <br />Burning (specify extent and location): <br />Angle of slope: 3:1 upstream, <br />PERIODIC INSPECTION FORM <br />Water, Sediment, or Slurry Impoundments <br />Circle or write in appropriate response <br />*Seepage (specify location, color, and approximate volume) <br />From underdrain pipes: <br />At isolated points on embankment slopes: <br />At natural hillside: <br />Over widespread areas: <br />From downstream foundation area: 5 ( oe lotJ <br />"Boils" beneath stream or ponded water: <br />Cracks or scarps on crest: <br />Cracks or scarps on slope: <br />Sloughing or bulging on slope: <br />*Major erosion problems: <br />Surface movements in valley bottom or on hillside: <br />*Erosion of toe: <br />*Water impounded against toe: <br />Existing embankment freeboard: <br />Increase Decrease in water level: <br />Cracks, bulging, or erosion on upstream face: <br />Visible sumps or sinkholes in slurry surface: <br />*Clogging <br />DATE LAST INSPECTION: <br />LOCATION: NW'% NWl %, Sec. 22, T5N, R88W <br />LOCATION: 8 mi. S of Hayden, CO <br />OWNER'S REP.: Roy Karo, Gen Mgr <br />Yes <br />12 in. <br />Yes <br />No <br />3:1 downstream Total = 6:1 <br />(normal = 7.5') <br />A Ir e I e_ l J V 0 v - r u e - O Q CI" 6 - ■ <br />trO t 41 i-J <br />6 1- 1 Z -l <br />N/A <br />Yes o N/A <br />Yes No N/A <br />Yes No) N/A <br />No N/A <br />Yes o N/A <br />Yes No N/A <br />Yes No N/A <br />Yes No N/A <br />Yes No N/A <br />Yes No N/A <br />Yes No N/A <br />Yes N/A <br />- 1.S feet <br />feet <br />Yes 0 N/A <br />N/A <br />Spillway channels and pipes: Yes V N/A <br />Decant system: N/A <br />Diversion ditches: Yes N/A <br />19. *Cracking or crushing of pipes <br />Spillway pipes: Yes No N/A <br />Decant system: N/A <br />20. Trash racks clear and in place: 4 No N/A <br />21. Discharge rate (gpm) . 6 <br />*Major adverse changes in these items could cause instability and should be reported to the <br />Engineering Manager and Mine Superintendent for further evaluation. Adverse conditions noted in <br />these items should normally be described (extent, location, volume, etc.) in the space on the <br />back of this sheet. <br />� II� f i f `� <br />