Laserfiche WebLink
18. *Clogging <br />Spillway channels and pipes: <br />Decant system: <br />Diversion ditches: <br />19. *Cracking or crushing of pipes <br />Spillway pipes: <br />Decant system: <br />20. Trash racks clear and in place: <br />21. Discharge rate (gpm) <br />PERIODIC INSPECTION FORM <br />Water, Sediment, or Slurry Impoundments <br />INSPECTOR'S NAME: Dennis Jones <br />NPDES I.D. NO.: N/A <br />FACILITY CONFIGURATION: Cross - Valley Pond <br />SITE NAME: Pond #012A <br />MINE NAME: Yoast Mine(Seneca Coal Co) <br />MINE I.D. NO.: CMLRD Permit No. C -94 -082 <br />DATE: C t` 1 - 1 1 <br />Circle or write in appropriate response <br />Over widespread areas: ��"" q <br />From downstream foundation area: �5e sz- ta W <br />"Boils" beneath stream or ponded water: <br />DATE LAST INSPECTION: 6-3o- <br />LOCATION: NEl /, NE' %,Sec. 19, TSN, R87W <br />LOCATION: 8.5 mi. SE of Hayden, CO <br />OWNER'S REP.: Roy Karo, Gen Mgr <br />1. Foundation preparation (removal of vegetation, stumps, topsoil: <br />2. Lift thickness: <br />3. Compaction according to approved plan: <br />4. Burning (specify extent and location): <br />5. Angle of slope: upstream, downstream <br />6. *Seepage (specify location, color, and approximate volume) <br />From underdrain pipes: <br />At isolated points on embankment slopes: <br />At natural hillside: <br />Yes <br />Yes <br />Yes <br />Yes <br />Yes <br />in. <br />Yes <br />No <br />Total = <br />No <br />N/A <br />N/A <br />N/A <br />N/A <br />N/A <br />Yes /1Go N/A <br />7. Cracks or scarps on crest: Yes No N/A <br />8. Cracks or scarps on slope: Yes No N/A <br />9. Sloughing or bulging on slope: Yes No N/A <br />10. *Major erosion problems: Yes No N/A <br />11. Surface movements in valley bottom or on hillside: Yes No N/A <br />12. *Erosion of toe: Yes No N/A <br />13. *Water impounded against toe: Yes o N/A <br />14. Existing embankment freeboard: (4.6' when full) /2, feet <br />15. Increase / Decrease in water level: g feet <br />16. Cracks, bulging, or erosion on upstream face: Yes ITC N/A <br />17. Visible sumps or sinkholes in slurry surface: N/A <br />Yes Info N/A <br />N/A <br />N/A <br />Yes No N/A <br />N/A <br />' > No N/A <br />0 <br />*Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manager and Mine Superintendent for further evaluation. Adverse <br />conditions noted in these items should normally be described (extent, location, volume, <br />etc.) in the space on the back of this sheet. <br />6, s a k0 eAn_C-Q__ C2CNLAA,_ 4.00 ‹t_ <br />c rQ &YS 4- h.oA C `-> k-s ; k w� ( <br />