My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-11-28_PERMIT FILE - C1992081A (10)
DRMS
>
Day Forward
>
Permit File
>
Coal
>
C1992081A
>
2011-11-28_PERMIT FILE - C1992081A (10)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:45:24 PM
Creation date
1/12/2012 12:11:52 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1992081A
IBM Index Class Name
Permit File
Doc Date
11/28/2011
Section_Exhibit Name
Tab 12 Facilities
Media Type
D
Archive
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
area exemption. <br />Railroad Loop: The railroad loop was constructed in the 1979/1980 period. All disturbance <br />associated with the construction of the loop has been topsoiled and successfully revegetated <br />with a stabilization seed mixture (identified as DHG [ Revegetated Hayden Gulch Disturbance) <br />in Tab 10, Vegetation) . Total revegetated area associated with the railroad loop is <br />approximately 70.8 acres. The disturbance area is shown on Exhibit 12 -1 (Revision 14, dated <br />03/07). <br />Runoff for a majority of the railroad loop does not drain to either of the sedimentation <br />structures. In order to demonstrate that the railroad loop meets the intention of the Rule <br />4.05.2(3), a SEDCAD+ analysis was conducted on the entire reclaimed section of the railroad <br />loop. <br />The SEDCAD+ analysis and all associated inputs are presented in Appendix 12 -2, Small Area <br />Exemption Demonstrations. As shown in the analysis, due to the successful revegetation <br />efforts the peak settleable solid concentration is below the water quality effluent standard <br />of 0.5 ml 11. Given these results HGTI requested, and received CDRMS approval to permit this <br />area as a small area exemption. <br />Areas I and 2: There are two small areas (Areas 1 and 2) which were disturbed during <br />40 construction of the loadout facilities area. The location of Areas 1 and 2 are shown on <br />Exhibit 12 -2, (Revision 11, dated 03/07). After construction of the Loadout, the areas were <br />topsoiled and successfully revegetated with the DHG stabilization seed mixture. Total <br />revegetated area associated with the Areas 1 and 2 is approximately 0.6 and 0.4 acres, <br />respectively. Runoff from these areas does not drain to either the Truck Loop Pond or the <br />Rail Loop Pond. In order to demonstrate that the areas meet the intention of the Rule <br />4.05.2(3), SEDCAD+ analyses were conducted on both revegetated sections., <br />The SEDCAD+ analyses and all associated inputs are presented in Appendix 12 -2, Small Area <br />Exemption Demonstration. As shown in the analysis, due to the successful revegetation <br />efforts, there is no runoff from either site. Given these results HGTI requested, and <br />received CDRMS approval to permit this area as a small area exemption. <br />HG Shallow Well No. 1 and Water Pipeline <br />A water - supply well and associated pipeline were installed in the 1978/1979 time period as <br />part of the original loadout facility construction activities by the previous owner/ <br />operator /permittee. Following installation, the disturbed ground was revegetated. The <br />locations of the water - supply well and associated pipeline corridor are shown on Exhibit 12- <br />1 (Revision 14, dated 03/07). <br />0 The estimated extent of the disturbed area are 0.34 acres for the HG Shallow Well No. 1 and <br />MR -15 5 Revised 03/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.