Doc Name
Pond 013 As Built Sedcad & SurvCad Hydrology Calculations for 10yr-24hr & 25yr-24hr Events
Section_Exhibit Name
Section 2.05.3(3) Attachment 2.05.3(3)-21
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conclusion <br />The size of Sediment Pond 013 was enlarged over the design to allow for additional sediment <br />storage so clean out frequency could be expanded upon. SEDCAD4 program was utilized in the <br />design to size the pond and to determine the size, location and placement of the gate valves, <br />Primary and Emergency Spillway Pipes. The SEDCAD4 10 & 25yr -24hr models can be viewed <br />within this document. SEDCAD4 shows that neither the 10yr or 25yr even reaches the top of the <br />Primary Riser. <br />Pond 013 embankment stability analysis for a Safety Factor was performed using the SB -Slope <br />stability software. A factor of safety in excess of 3 to 1 was calculated for the As- Built. Well above <br />the required 1.3 that is stated in 4.05.9(8)(b). <br />I, Ross L. Gubka, P.E., was on the construction site of Pond 013 the entire time as W FC's <br />company representative. I have a wide variety of experience in the design and construction of <br />earth fill embankment and impoundments. Nothing was observed during the inspections that would <br />indicated the pond has a potential for failure. The sediment pond was constructed in accordance <br />with the applicable regulations during October and November 2007. The design of the sediment <br />pond is shown in Attachment 2.05.3(3) -21 and in Map 2.05.3(3) -18. <br />/ L�LOB <br />Ross L. Gub�y Date <br />Colorado Professional Engineer <br />Registration No. 28950 <br />Attaclunent 2.05.3(3) -21 -6 <br />Attachment 2.05.3(3) -21 -6 <br />