Piezometer <br />Date <br />Time <br />Cumulative <br />Gallons <br />Removed <br />pH <br />Conductivity <br />(mS /cm). <br />Temperature <br />( °C) <br />Dissolved <br />Oxygen <br />(mg /L) <br />IC- 10300R <br />8/15/2011 <br />17:18 <br />75 <br />6.92 <br />1.913 <br />8.26 <br />2.22 <br />IC- 10300R <br />8/15/2011 <br />17:23 <br />80 <br />9.79 <br />1.909 <br />8.21 <br />2.59 <br />IC- 10300R <br />8/15/2011 <br />17:28 <br />85 <br />6.75 <br />1.909 <br />8.29 <br />2.42 <br />IC- 10300R <br />8/15/2011 <br />17:33 <br />90 <br />6.84 <br />1.909 <br />8.23 <br />2.64 <br />IC- 10300R <br />8/15/2011 <br />17:38 <br />95 <br />6.84 <br />1.905 <br />8.18 <br />2.45 <br />IC- 10300R <br />8/15/2011 <br />17:43 <br />100 <br />6.81 <br />1.912 <br />8.2 <br />2.89 <br />IC- 10370R <br />8/16/2011 <br />12:00 <br />60 <br />9.76 <br />2.878 <br />10.16 <br />1.4 <br />IC- 10370R <br />8/16/2011 <br />12:05 <br />65 <br />6.7 <br />2.877 <br />10.09 <br />1.53 <br />IC- 10370R <br />8/16/2011 <br />12:10 <br />70 <br />6.76 <br />2.861 <br />11.42 <br />1.59 <br />IC- 10370R <br />8/16/2011 <br />12:15 <br />75 <br />6.72 <br />2.852 <br />11.24 <br />1.6 <br />IC- 10370R <br />8/16/2011 <br />12:20 <br />80 <br />6.65 <br />2.865 <br />12.13 <br />1.01 <br />IC- 10370R <br />8/16/2011 <br />12:25 <br />85 <br />6.85 <br />2.853 <br />12.06 <br />1.5 <br />ARCADIS <br />Table D - Field Parameter Stabilization During <br />r Develo <br />The total volume of water removed from IC- 10300R was approximately 100 gallons, or <br />a total of 5 well casing volumes. A slug and bailer were used to extract approximately <br />25 gallons of turbid water. The well began to clear after 25 gallons and an impeller <br />pump was used to produce approximately 75 gallons of water (or approximately 4.5 <br />well casing volumes). The pumping rate during development of IC- 10300R was <br />approximately 1 gallon per minute (gpm). The piezometer quickly recovered to static <br />water level after development. <br />The total volume of water removed from IC- 10370R was approximately 105 gallons, or <br />a total of approximately 10 well casing volumes. A slug and bailer were used to extract <br />approximately 25 gallons of turbid water. The well began to clear after 25 gallons and <br />an impeller pump was used to produce the rest of the total volume. The pumping rate <br />during development of IC- 10370R was approximately 1 gallon per minute (gpm). The <br />piezometer quickly recovered to static water level after development. <br />gAapmjectlbarrick\ao000102.0001 pitch reclamation pmjecttao102, banick- pilch1piezo replacement reportingWreXlfar pitch_piezo_replacement_pdd.doc <br />Pitch Reclamation Project - <br />Piezometer Replacement <br />Field Activities Report <br />10 <br />