DESIGN CRITERIA <br />Code: <br />Location: <br />Jurisdiction: <br />Occupancy Category. <br />Floor Uwe Loads <br />Roof Live Loads: <br />Wind: <br />Seismic: <br />GENERAL CONDITIONS AND REQUIREMENTS <br />International Building Code (IBC). 2009 Edition <br />Parchall, CO <br />Grand County <br />Mechanical Access <br />Mechanicd Equipment <br />Ground Snow, Pg <br />Snow Exposure. Ca <br />Snow Importance <br />Thermal Factor. Ct <br />Flat Root Snow. Pf <br />Velocity (3 sec. gust) <br />Exposure <br />Wind Importance <br />Internal Pressure Coefficient <br />Component /Cladding <br />Component /Cladding loads <br />Spectral Response S. <br />Spectral Response S1 <br />Site Class <br />Spectral Response SDS <br />Spectral Response SDI <br />Selemlc Importance <br />Seismic Design Category <br />Force Resisting System(s) <br />Response Coeff. CS <br />Analysis Procedure <br />Design Base Shear <br />75 pet uniform <br />Noted on drawings <br />70 pet (el. 9176' -6') <br />1.0 <br />1.0 <br />1.0 <br />70 pef <br />90 mph <br />C <br />1.0 <br />±0.18 <br />±30.4 psf at enclosed walls <br />±51.9 pet at enclosed roots <br />±43.0 psi at roof overhangs <br />for other areas are subject to review <br />0.267 g <br />0.065 g <br />B <br />0.178 9 <br />0.043 g <br />1.0 <br />Steel OMRF <br />Equivalent Lateral Force <br />Cs x W <br />1. The use of these drawings constitutes a contractual agreement between the Contractor <br />and the Owner. Thus, these Contract Documents take precedence over trade practices <br />and third party specification.. <br />2. The term Engines shdl be taken to mean the Structural Engineer of Record. Third <br />part entitles are specifically noted as 'Professional Engineer, 'Contractor'e Engineer; <br />Designer; etc. <br />3. Contractor is responsible for obtaining access to all codes, standards specifications, <br />reports, third party literature, etc. referenced In these documents. <br />4. Contractor shall field measure and verify all existing conditions and dimensions at job <br />site. In the event that existing conditions or dimensions wry from those shown on <br />the drawings, Contractor shall notify the Engineer so proper adjuatmente can be made. <br />5. Contractor shall check and verify all dimensions and other Information shown on <br />structural drawings with those shown on non - structural drawings. Including <br />architectural and other disciplines. Contractor shall notify the Engineer of any <br />dlscrepanclea between structural and non - structural drawings. or within structural <br />drawings Where euch discrepancies occur, the most stringent requirements shall <br />govern unless written clarification Is obtained from the Engineer. <br />6. All Contractors, Subcontractors, Fabricators, Suppliers and other Jobslte personnel shall <br />of all times comply with the Occupational Safety and Health Administratlon `OSHA) <br />Standards - 29 CFR, Parts 1910 Occupational Safety and Health Standards) and <br />1926 ('Safety and Health Regulation, for Constriction ). <br />7. Drawings represent a finished product. and do not address the means and methods <br />necessary to complete the construction. During erection of the structure, the <br />Contractor shall be responsible for temporary bracing to withstand all loads to which <br />the structure may be subjected. Including lateral loads. stockpiles of materials and <br />equipment. Such bracing shall be left In place as long as required for safety. and <br />until all structural framing and diaphragms are In place with connections complete. <br />8. The term provide' as used herein shall mean that Contractor shall furnish and <br />Install sold item, Including all construction. equipment, materials, etc., for a complete, <br />finished Installation. <br />9. Installation of proprietary products shalt comply with all manufacturers specifications <br />and recommendations, unless noted otherwise. Product substitutions shall be subject <br />to Engineers review. <br />10. Detaile noted 'typical' apply to all comparable conditions. Where no specific details <br />are shown, construction shall conform to the comparable work defined elsewhere on <br />the project. <br />11. Deviations from these Contract Documents are not permitted. unless coordinated with <br />the Architect or Engineer. <br />12. Third Party Quality Control: Contractor shall provide Engineer with copies of all third <br />party structural field observation reports and test results immediately upon receipt. <br />13. Third Party Engineered Systems: All references to 'Professional Engineer' or 'P.E' <br />shall be taken to mean a Professional Engineer currently registered In the project's <br />Jurisdiction with experience In the specific discipline of the engineered system. <br />14. Construction documents are copyrighted and shall not be reproduced without written <br />authorization from the Engineer. <br />15. Iteme requiring review by the Engineer, such as shop drawings. product substitutions, <br />requests for field obeervatlons, etc., shall be brought to the Engineers attention with <br />sufficient notice to allow the Engineer a reasonable review period. <br />16. The Engineer's scope of services does not Include design and /or analysis of conditions <br />resulting from Contractor errors or changes, nor does It include review of reissued <br />submittals that were originally rejected. in these cases, the Contractor shall be <br />subject to reimbursing the Owner for additional services incurred by the Engineer. <br />17. Structural drawing. are not stand -alone documents and are intended to be used In <br />conjunction with Civil. Architectural. Mechanical and Electrical drawings, plus all <br />drawings from other disciplines. Structural materials that are used in non - structural <br />applications are subject to the Structural General Note,. The Contractor shall <br />coordinate ail requirements of the Contract Documents Into the Work <br />18. Coordinate size and location of all openings. biodrouts, floor depressions, curbs, etc. <br />with Civil, Architectural, MechanIcal, Electrical drawings, etc. as applicable, and reinforce <br />these Items as shown on the Structurd drawings, or as required by Code. Holes, <br />notches, blockouts etc. are prohibited In structural members unless specifically shown <br />on the drawing, or coordinated with the Engineer. <br />19.0o not scale drawings. <br />20.See architecturd drawing, for non- etructurd partitions. Non - structural partition <br />shall be Installed with slip connections that permit framing live load deflections of <br />L/240. <br />21. %here discrepancies exist among Drawings, General Notes and Specifications, the most <br />stringent requirements shall govern. <br />22.These General Notes provide supplemental information to that presented In the <br />Specifications. See Specifications for additional information and requirements. <br />FOUNDATION <br />1. See Geotechnical Report Number DN44,981 -125, dated June 25, 2010, prepared by CTL <br />Thompson, Inc., for additional information and requirements. <br />2. Assumed sell capacities for use with mlcropiles: <br />Maximum end bearing = 75,000 pef. <br />Maximum side friction in bedrock formation = 6,000 pef. <br />3. A Geotechnical Engineer must be present while microplee are being drilled to <br />determine bedrock elevation, and to review placement of reinforcement. Concrete shall <br />be placed as soon as as possible after pier excavation Is complete, but not until <br />approval by Geotechnical Engineer. <br />4. The center of micropile shall not deviate from the required position by more than <br />1 l/2' and mlcroplles shall not be out of plumb by more than 1 to 100. All mlcrapile <br />excavations shall be dean and dewatered before placing concrete. If this Is not <br />possible, concrete shall be tremied below the standing water. Any casing used during <br />the drilling shall be pulled as concrete is being placed. <br />5. No concrete shall be poured In excavation containing water or on frozen ground. <br />6. Backfill shall be placed against both sides of walls simultaneously. Use only hand - <br />operated tools for compaction adjacent to foundation walla. Do not bac ttl until <br />building walls have cured a minimum of 7 days. <br />7. Refer to Geotechnical Report, Architectural Drawings and /or Civil Drawings for complete <br />site grading, drainage, subgrode preparation and engineered fill requirements. Slope <br />exterior grades away from foundation In all directions. All roof downspouts and drains <br />shall discharge well beyond the limits of all backfill, and not be allowed to pond <br />adjacent to the building. <br />8. At slabs -on -grade, locate slip joints at all partitions in accordance with Geatechnlcal <br />Report. <br />9. Slabs -on -grade shall be isolated from foundation with 1/2' expansion Joint material. <br />CONCRETE <br />1. Material and workmanship shall be In accordance with the requirements of 'Building <br />Code Requirements for Reinforced Concrete' (ACI 318, latest edition), and <br />'Specifications for Strucutral Concrete' (ACI 301, latest edition). <br />2. Concrete shall have a minimum compressive strength (fc) at the age of 28 days as <br />follows: <br />All slabs 4000 psi <br />All foundation walls 4000 pal <br />All micropiles 5000 pal <br />Concrete exposed to freeze -thaw cycles shall have an air content of 4-6X. Concrete <br />shall be normal weight (145 pct), unless noted otherwise. <br />3. All cement used In foundations shall conform to ASTM C 150 Type II. <br />4. All concrete shall have a minimum cement content of 470 lbs. per cubic yard, unless <br />noted otherwise. Cement shall consist of no more than 20% fly ash. <br />5. Calcium Chloride shall not be added to concrete. <br />6. Reinforcing bare shall be deformed bars and shall conform to ASTM A 615, Grade 60. <br />unless noted otherwise. All stirrups and column ties shall conform to ASTM A 615, <br />Grade 40. Weldable reinforcement shall conform to ASIA A 706, Grade 80. <br />7. Reinforcing bars shall be detailed on the shop drawings in accordance with the <br />American Concrete institute 'ACI Detailing Manual' (ACI SP -66, latest edition), unless <br />noted otherwise. <br />8. Welded wire fabric shall conform to ASTIR A 185, shall lap a minimum of one full mesh <br />plus 2 Inches at side and and laps, and Mall be securely wired together. unless noted <br />otherwise. <br />9. Cant -in -place steel anchor bolts shall conform to ASTM F 1554, Grade 38, unless <br />noted otherwise. <br />10. Bar bending details and placing drawings shall be In accordance with the 'Manual of <br />Standard Practice for Detailing Reinforced Concrete Structures' (ACI 315, latest edition). <br />11. Bar supports, chairs, spacer. and rebar positioners shall be used to place all bare in <br />the exact location specified on the drawings. Wire adequately at intersections to hold <br />bars firmly In position while concrete is placed. <br />12. Bar supports, chairs and spacers which rest on or against an exposed surface shall be <br />hot - dipped galvanized. <br />13. Continuous bare Mall lap and dowels shall protect adequately to provide a Class B <br />splice. but not less than 12 Inches, unless noted otherwise. <br />14. Stirrups, ties, footing dowels and cantilevered reinforcement shall terminate in a <br />standard hook at the free end(s) of the bar, unless noted otherwise. <br />15. Where lap splice locations of horizontd bare are not spedflcdly noted on the drawings, <br />lap splices are to be staggered. <br />16. Concrete cover for reinforcement shall be as follows, subject to the tolerances of ACI <br />117, unless noted otherwise: <br />A. Concrete poured against earth 3' <br />B. Concrete poured In forms but exposed to weather or earth <br />(1.) #5 bars or smaller 1 1/2' <br />(2.) Bars larger than #5 2' <br />C. Columns, girders and beams (principal reinforcement, ties <br />and stirrups) 1 1/2' <br />D. Robe and walls 3/4' <br />17. See architectural, mechanical and electrical drawings for additional openings. <br />depressions, curbs, floor finishes, Inserts and other embedded Items. <br />18. When other reinforcing is not required by the drawings. (2) #5 ban shall be located <br />at all sides of, and adjacent to, every opening that exceed, 24' In either direction. <br />Extend ban 24' beyond each side of opening. <br />19.Unleee noted otherwise, di concrete slabs are to be reinforced with W.W.F. 606 - <br />W1.4xW1.4. centered In slab depth. <br />20. Where welded reinforcement or deformed bar anchors are Indicated on the drawings, <br />steel specifications and welding shall conform to the 'Structural Welding Code - <br />Reinforcing Steel' (AWS D1.4, latest edition) of the American Welding Society. <br />GENERAL NOTES <br />MASONRY <br />1. Material and workmanship shall be In accordance with the requirements of the 'Building <br />Code Requirements for Masonry Structures' (ACI 530, latest edition). and the <br />'Specification for Masonry Structures' (ACI 530.1, latest edition). <br />2. All masonry block units shall be lightweight (105 pcf) and conform to AST I C 90, with <br />a minimum net area compressive strength of 1900 psi. <br />3. Mortar for all masonry wails shall conform to ASIA C 270, Cement -Lime Type S. with <br />a minimum compreaaln strength of 1800 pal at the age of 28 days. <br />4. All grout shall attain a minimum compressive strength (re) of 3000 pal at the age of <br />28 days. Grout shall be proportioned by volume and shall haw sufficient water added <br />to produce consistency for pouring without segregation. <br />A. Coarse grout shall be composed of one part portiand cement, 2 1/4 to 3 <br />parte sand. and 1 to 2 parts pea grovel. <br />B. Fine grout shall be composed of one part portland cement, and 2 1/4 to <br />3 parts sand. <br />5. All masonry shall develop 1500 psi ultimate compressive strength (fm) at the age of <br />28 days. Compressive strength shall be verified by prism tests In accordance with <br />Chapter 17 of the International Building Code. <br />6. Reinforcing steel shall be deformed bare conforming to ASTM A 615, Grade 60. unless <br />noted otherwise. <br />7. Minimum horizontal reinforcing shall be Dur- o-Wail '#9 gage Ladur -Type bed joint <br />reinforcing of 16' c.c., or approved equivalent, and shall conform to ASTM A 82. <br />6. Reinforcing steel lap splices shall be as follows: 29' for /4 bars, 45' for #5 bare and <br />65' for #6 bars. unless noted otherwise. For Grade 40 bare, lap splices are permitted <br />to be two-thirds of the above lengths. <br />9. Shop Drawings. Contractor shall submit shop drawings for steal reinforcement showing <br />each piece, Its size, length and location. Include wall elevations and /or sections <br />howing proposed splice locations and lap lengths. <br />10. Vertical cells to be grouted shall have a vertical alignment to maintain a continuous <br />unobstructed call area not leas than 3'4' for 6' units 5'x5' for 8' unite, and 9'x5' <br />for 12' units. <br />11. Reinforcing steel shall be In place and Inspected before grouting starts. All debris and <br />mortar shall be cleaned out before pouring grout. Cleanout openings shall be located <br />at the bottom of all cells to be filled of each pour of grout In excess of five feet in <br />height. Reber poslaoners shall be used at top and bottom of reinforcing bars and at <br />apacings not to exceed 10' -0' when grout pour is in excess of five feet in height. <br />12. When a foundation dowel does not line up with the vertical core to be reinforced, it <br />shall not be bent over, but shall be grouted into a core in direct vertical alignment, <br />even though It Is an adjacent cell to the vertical wall reinforcing. <br />13. Celle containing reinforcement shall be solidly filled with grout In lifts not to exceed <br />6' -0' and pours not to exceed 24' -0'. Pours shall be stopped 1 1/2' below the top <br />of a course to form o key at pour joints. Grout shall be consolidated at time of <br />pouring by mechanical vibration and then reconsolidated by again vibrating within 5 to <br />8 minutes of initial consolidation. <br />14. Where other reinforcing is not required by the drawlnps, locate (2) #5 bars at all sides <br />of, and adjacent to, every opening which exceeds 24 in wither direction. Extend bare <br />24' beyond each side of the opening. <br />15. All interior masonry partitions shall be reinforced with /4 vertical bars at 8' -0' o.c.. <br />with slip joints at 4' -0' 0.0. maximum, unless noted otherwise. <br />16. Bond beams are required at top and bottom of all openings (continued 2' -6' beyond <br />each side of opening), along all diaphragms, at top of wall and at 8' -0' o.c. max. <br />Reinforce with (2) #5 unless noted otherwise. Bars to be continuous around corners. <br />17. Grout solid all cells and courses a distance of 24' below and 12' each side of all <br />beam reactions and concentrated loads, unless noted otherwise. <br />18. Vertical control joints shall be located within 16' of corners and at 20' -0' o.c. max. <br />Control joints shall not be located within 16' of openings <br />STRUCTURAL STEEL <br />1. All detailing, fabrication and erection shall conform to American institute of Steel <br />Construction Specifications for Structural Steel Buildings' (RISC 360) and the 'Code <br />of Standard Practice for Steel Buildings and Bridges' (AISC 303), latest editions. All <br />bolting shall conform to the Research Council on Structural Connections 'Specification <br />for Structural Joints Using AS1M A325 or A490 Bolts' (RCSC A.1), latest edition. <br />2. All steel shall conform to the following ASTM standards, unless noted otherwise: <br />All steel not otherwise shown ASTM A 36 <br />W and VAT shapes AS11A A 992 <br />Steel Tubing ASTM A 500, Grade B <br />Steel Pipe AS1M A 53 (Type E or 5), Grade B <br />3. Structural steel bolts shall conform to ASTM A 325, heavy hex. Nuts shall conform to <br />ASTM A 563, heavy hex. Washers shall conform to ASTM F 436. Bolted assemblies <br />shall be 3/4'11 unless noted otherwise. <br />4. Bolted connections shall be snug tight, unless noted otherwlee. <br />5. All welding shall conform to the American Welding Society 'Structural Welding Code' <br />(AWS D1.1), latest edition. Welding shall be performed with E70xx electrodes unless <br />noted otherwise. <br />6. All steel shall receive one shop coat of fabricators standard primer, such as Tnenec <br />10-99 or Rust-Oleum 1069 red metal primer, except at areas to be field welded. <br />7. Areas within 2 Inches of field welds shall not be painted until after welding. Field <br />welds, bolt heads, nuts all other surfaces not shop pointed, and all surfaces that <br />become abraded during shipping and erection shall be field painted Immediately after <br />erection. <br />8. Shop connections shall be welded unless noted otherwise. <br />9. All welding shall be done by certified welding operators, who each have In their <br />possession current evidence of passing the American Welding Society Standard <br />Qualifications Tests' as detailed In ANS D1.1. Welding certificates shall be submitted <br />to the Engineer for each welder before field welding commences. <br />10. Weld sizes not otherwise shown shall be minimum continuous 5/16 Inch fillet welds. <br />11. Heat - Induced field fabrication (including, but not limited to, holes, coping and trimming <br />of steel members) shall be prohibited unless specifically coordinated with Engineer. <br />12. The Engineer shall be notified whenever base metal discontinuities, fit -up and <br />alignment problems, field welding problems, or member length or hole alignment Issues <br />are Identified during erection of the building. Written clarification must be obtained <br />before proceeding with field modification. of the structural steel. <br />13. Non - shrink grout shall conform to ASTM C 1107, with a minimum ultimate compressive <br />strength of 5.000 psi at the age of 28 days. <br />14. Substituted beam connections shall be subject to review by Engineer. Shear <br />connection, shall conform to Part 10 of the AISC 'Steel Construction Manual; latest <br />edition. Moment connections shall conform to Part 12. All substituted connections <br />must develop the full capacity of the connections specified on the structural drawings. <br />15. Grating shall be welded rectangular design, steel. Main bars to be 1' x 3/16', spaced <br />at 1 3/16' center to center. Cross bare are to be spaced at 4' o.c. Grating to be <br />fastened to each steel support beam with 3/16' x 1' fillet weld at 24' o.c. <br />16. Stair treads shall conform with grating requirements, unless noted otherwise. Use <br />checkerpiate nosing. <br />SUBMITTALS <br />1. General Contractor shall check and stamp all shop drawings before submitting to <br />Engineer. Unchecked submittals and /or submittals that substantially deviate from the <br />Contract Documents will be returned without review. <br />2. As a minimum, shop drawings shall include comprehensive layouts, member sizes. <br />fabrication requirements and connections as required to demonstrate a complete <br />understanding of the structural system to be constructed. Refer to individual material <br />general notes for additional requirements. <br />3. Product catalog pages and reproductions of Contract Documents do not demonstrate <br />the required understanding of the structural Intent, and will be retumed without review. <br />4. General Contractor shall submit shop drawings and proprietary documentation in a <br />timely manner to permit minimum ten working days for review by Engineer. Contractor <br />Shall coordinate construction schedule to account for correction of errors and <br />reaubmlttale, If required. <br />5. Engineer's review of shop drawings does not relieve Contractor of responsibility to <br />follow all requirements of the Contract Documents. <br />6. General Contractor shall submit In writing any requests to modify the Contract <br />Documents. Such requests shall not be considered accepted until they have been <br />specifically addressed by the Engineer. Shop drawings alone do not constitute 'In <br />writing'. unless specific proposed changes are clearly identified. Proposed changes <br />shall be coordinated by the individual initiating the change. <br />INSPECTOR AND SPECIAL INSPECTION <br />1. All Inspection shall conform to the requirements of Section 109 of the International <br />Building Code. All Special Inspection shall conform to the requirement. of Section <br />1704 of the intemational Building Code. <br />2. The owner Is required to employ Inspectors and special Inspectors. who shall submit <br />copies of all reports to the owner, architect, structural engineer. and the Building <br />Department. Upon completion of their scrape of work, the inspectors and special <br />inspectors shall submit a final signed report stating whether the work was, to the best <br />of their knowledge. In conformance with the approved set of Contract Documents and <br />the applicable workmanship provisions of the Building Code. <br />3. Inspectors and special Inspectors shall be qualified person(s) who demonstrate <br />competence In their respective two of construction to the satisfaction of the <br />Building Official. <br />4. The General Contractor shall coordinate with Inspectors and special Inspectors to <br />Incorporate the inspection schedule into the overall project construction schedule. <br />5. Special Inspection la required for, but not limited to, the following types of work. <br />Refer to the project specifications and the IBC for additional Information regarding <br />testing and inspection requirements. <br />Soil preparation Table 1704.7 <br />Drilled piers / mlaopiles. Table 1704.9 <br />Structural concrete Section 109.3.1, Section 109.3.2, Table 1704.4 <br />Structural masonry Table 1704.5.1 <br />Structural steel fabricator Section 1704.2 <br />Structural steel construction Section 109.3.4, Table 1704.3 <br />6. The Engineer of Record shall not be considered a Special inspector. <br />7. The Engineer of Record shall be provided Jobelte access to conduct quality assurance. <br />This drawing together with any and all additions, correc- <br />tions, changes and alterations thereof is the property of <br />Climax Molybdenum Co. and is furnished on the express <br />condition that it shall not be reproduced, copied, lent, or <br />disposed of directly or indirectly, nor used for any other <br />purpose than for which it is specifically furnished without <br />prior written consent of said Climax Molybdenum Co. <br />REFERENCE DRAWINGS <br />DESCRIPTION OF REVISION <br />f <br />2 <br />3 <br />4 <br />5 <br />DATE <br />BY <br />SCALE <br />PLOT SCALE <br />INVERT OF SCALE <br />COMPUTER FILE: <br />.DWG <br />PAPER SIZE D <br />ENGINEER: <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />APPROVED BY: <br />DATE <br />CLIMAX MOLYBDENUM COMPANY <br />19302 COUNTY ROAD No. 3 <br />PARSHALL, CO <br />(303) 569 -3221 <br />SHEET No. <br />NO. <br />6931 <br />ERE <br />MIMI 1 <br />MEI 2 <br />ELI <br />132 4 <br />126085 <br />2236 <br />221114 <br />2502 a <br />RE ON= - 188U68 <br />DATE <br />26 -18-10 <br />06-2-10 <br />06 -9)-10 <br />all -01-10 <br />08 -16-10 <br />11-09 -10 <br />u -29-I0 <br />12 -17 -10 <br />12-12 -11 <br />05-08-1 <br />DESCRIPTION <br />Par <br />ND <br />1119 I <br />MOM 2 <br />1 <br />921911 ION MRS <br />EMU, Bin= <br />699 <br />a 4 <br />WED 911t0iCi <br />BAUR & ASSOCIATES <br />CONSULTING ENGINEERS <br />2551 31st Soto Boulder, CO 80301 <br />103- 444 -9121 (4 303 - 415 -1070 i1) <br />a.jcbaur.com <br />ISVISIOnt sesa Ma at <br />on a tea toe geo p r r� and <br />m Oaks eaa N snot a b b err <br />contras= bo a mans curs nr at <br />PROJECT: <br />LLE BLAKER <br />f .134D078ON p L <br />117302 COUNTY RD. <br />NO. 3 <br />PAR81ALL CO <br />DATE: <br />08±88: <br />CRECEED: <br />00 -Is-10 <br />NE8 <br />RW <br />// OREE TIME <br />M�y � �� <br />Ci.1QAL <br />NO1E8 <br />PROWL' 110. <br />NOTED <br />IODEE <br />I DRAWING N0. <br />T1.1 <br />HENDERSON MILL SITE <br />LIME SLAKER PROJECT <br />DWG No. <br />REV. Let. <br />