Search
2003-07-29_HYDROLOGY - M1977493
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977493
>
2003-07-29_HYDROLOGY - M1977493
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:15:44 PM
Creation date
11/1/2011 7:30:19 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977493
IBM Index Class Name
HYDROLOGY
Doc Date
7/29/2003
Doc Name
Robinson Dam
From
DWR
To
Climax
Permit Index Doc Type
Hydrology Report
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DAM NAME: ROBINSON <br />W <br />U � <br />ZQ <br />Zw <br />LU cc. <br />1- 0 <br />Z <br />QQ <br />O) <br />J2 <br />O <br />E- <br />a <br />2 <br />• O <br />U <br />PROBLEMS NOTED: J(60 NONE ❑ (61) ACCESS ROAD NEEDS MAINTENANCE ❑ (62) CATTLE DAMAGE <br />0(63) BRUSH ON UPSTREAM SLOPE, CREST, DOWNSTREAM SLOPE, TOE 0(64) TREES ON UPSTREAM SLOPE, CREST, DOWNSTREAM SLOPE, TOE <br />J(67) GATE AND OPERATING MECHANISM NEED MAINTENANCE 0(68) OTHER <br />Usual rodent activity in area at the toe of the downstream slope between the spillway and maximum <br />section of dam. See page 3. <br />0 (71) SATISFACTORY <br />O <br />p, y 01 4 <br />o 0 p <br />N y • 0 5 0 <br />Go . D a <br />a <br />OA 0 N , s <br />, ▪ 6 2 <br />d v O O E <br />o • b u. N O <br />O d 4 BIZ <br />N 01 O <br />U N 4 E C <br />N -C S q a <br />v 4 <br />0 . E <br />d 0 - y <br />N N o. .a--• <br />E O o O <br />v V E .E <br />CI e y N <br />C r <br />O <br />11 2 <br />YI a O <br />. � • . <br />d % v W Y <br />< Ito <br />'.i. <br />W N= V •• <br />y• <br />ip <br />to 0 N= <br />Go H .c <br />• , o 3O <br />Engineer's <br />Signature <br />EXISTING INSTRUMENTATION FOUND 7(110) NONE i [1(111) GAGE ROD L(112) PIEZOMETERS *(113) SEEPAGE WEIRS / FLUMES <br />(114) SURVEY MONUMENTS [ (115) OTHER <br />MONITORING OF INSTRUMENTATION C] (116) NO *(117) YES PERIODIC INSPECTIONS BY: � / (118) OWNER *(119 ENGINEER <br />Monuments need to be resurveyed and report submitted to our office. <br />(65) RODENT ACTIVITY ON UPSTREAM SLOPE, CREST, DOWNSTREAM SLOPE mg ❑ (66) DETERIORATED CONCRETE - FACING, OUTLET SPILLWAY <br />Dam is in satisfactory condition, but unknown condition of old outlet, with its intake buried in silt, has been <br />neglected for many years warrants conditionally satisfactory rating. Also condition of siphon is unknown. <br />Based on this Safety Inspection and recent file review, the overall condition is determined to be: <br />MAINTENANCE • MINOR REPAIR • MONITORING <br />❑ (80) PROVIDE ADDITIONAL RIPRAP: <br />O (81) LUBRICATE AND OPERATE OUTLET GATES THROUGH FULL CYCLE <br />0(82) CLEAR TREES AND /OR BRUSH FROM: <br />(83) INITIATE RODENT CONTROL PROGRAM AND PROPERLY BACKFILL EXISTING HOLES: downstream slope & toe <br />V (84) GRADE CREST TO A UNIFORM ELEVATION WITH DRAINAGE TO THE UPSTREAM SLOPE:. Add more road base to make it easier to maintain <br />[1(85) PROVIDE SURFACE DRAINAGE FOR: <br />0 (86) MONITOR: <br />(88) OTHER <br />J(89) OTHER <br />ENGINEERING • EMPLOY AN ENGINEER EXPERIENCED IN DESIGN AND CONSTRUCTION OF DAMS TO: (Plans and Specifications must be approved by State Engineer prior to construction.) <br />❑ (90) PREPARE PLANS AND SPECIFICATIONS FOR REHABILITATION OF THE DAM: <br />0(91) PREPARE AS -BUILT DRAWINGS OF: <br />El (92) PERFORM A GEOTECHNICAL INVESTIGATION TO EVALUATE THE STABILITY OF THE DAM: <br />0 (93) PERFORM A HYDROLOGIC STUDY TO DETERMINE REQUIRED SPILLWAY SIZE: <br />0 (94) PREPARE PLANS AND SPECIFICATIONS FOR AN ADEQUATE SPILLWAY: <br />❑ (95) SET UP A MONITORING SYSTEM INCLUDING WORK SHEETS, REDUCED DATA AND GRAPHED RESULTS: <br />n (96) PERFORM AN INTERNAL INSPECTION OF THE OUTLET: <br />L� (99) OTHER: <br />SAFE STORAGE LEVEL RECOMMENDED AS A RESULT OF THIS INSPECTION <br />0(101) FULL STORAGE <br />* (102) CONDITIONAL FULL STORAGE <br />ID (103) RECOMMENDED RESTRICTION <br />El (104) CONTINUE EXISTING RESTRICTION <br />REASON FOR RESTRICTION <br />ACTIONS REQUIRED FOR CONDITIONAL FULL STORAGE P^ <br />Items (97) and (96) <br />(87) DEVELOP AND SUBMIT AN EMERGENCY PREPAREDNESS PLAN: Update plan as changes occur <br />remove old pipeline from dam crest near the spillway to make crest regrading easier. <br />Uncover outlet Intake <br />(97) OTHER: For outlet inspection, construct cofferdam as planned under direction of engineer <br />(98) OTHER: The submittal of plans and specs for item (97) are not required <br />Page 2 <br />ITEMS REQUIRING ACTION BY OWNER <br />TO IMPROVE THE SAFETY OF THE DAM <br />DAM I.D.: 370107 <br />(72) CONDITIONALLY SATISFACTORY 0(73) UNSATISFACTORY <br />Both old pipe & siphon. Keep us aprised of inspection & submit report <br />Owner's <br />Signature <br />FT. BELOW DAM CREST <br />FT. BELOW SPILLWAY CREST <br />FT. GAGE HEIGHT <br />NO STORAGE - MAINTAIN OUTLET FULLY OPEN <br />INSPECTED BY OWNER/OWNER'S REPRESENTATIVE <br />DATE. 7/17/2003 7 <br />DATE: <br />pp 2 of <br />
The URL can be used to link to this page
Your browser does not support the video tag.