Laserfiche WebLink
CONTENTS: RESULTS OF MONTHLY FIELD TESTS and ANNUAL TESTING, <br />FLOW RATE CALCULATIONS and FLOW RATE HYDROGRAPH <br />SITE: SW -N103 <br />LOCATION: Lower Calimity Draw <br />Located approximately 2/3 mile west of 27 & CC <br />intersection, where stream crosses CC road <br />Date of Collection <br />FIELD PARAMETERS <br />PH 8.48 7.98 <br />Water Temperature (deg C) 5.0 16.4 <br />Conductivity (umhos /cm) 3270 1287 <br />Instantaneous Flow (cfs) 0.000 0.000 0.000 0.000 1.462 0.000 0.000 0.000 0.000 0.000 8.565 0.000 <br />LABORATORY PARAMETERS <br />Metals Analysis MDL'S Units <br />Aluminum, total recoverable (mg /L) .10(B) 1.6 0.0300 mgt <br />Calcium, dissolved (mg /L) 416 204 0.2 mgt <br />Iron, dissolved (mg /L) 0.16 0.04(B) 0.02 met <br />Iron, Total Recoverable 0.33 1.42 0.02 mgt <br />Lead, Total Recoverable (mg /L) .0.0003(B) 0.0022 0.0001 out <br />Magnesium, dissolved (mg /L) 220 63.1 0.2 mgt <br />Manganese, total recoverable (mg /L) 1 0.354 0.0050 mgt <br />Molybdenum, dissolved (mg /L) 0.01(B) U 0.01 mgt <br />Potassium (mg /L) 4.8 3.4 0.30 mgt <br />Selenium, dissolved (mg /L) U 0.0005 0.0001 mgt <br />Sodium, dissolved (mg /L) 120 42.6 0.3 mgt <br />Wet Chemistry <br />Bicarbonate as CaCO3 <br />Carbonate as CaCO3 <br />Hydroxide as CaCO3 <br />Total Alkalinity <br />Ammonia as N, unionized <br />Cation -Anion Balance <br />Sum of Anions <br />Sum of Cations <br />Chloride <br />Conductivity @25C <br />Hardness as CaCO3 <br />Nitrite as N, dissolved <br />Nitrate/Nitrite as N, dissolve <br />Nitrite as N, dissolved <br />Nitrogen, Ammonia (Ionized) <br />pH (lab) <br />Phosphate <br />Phosphorus, ortho dissolved <br />Residue, Filterable (TDS) @180 <br />Residue, Non - Filterable (TSS) <br />Sodium Absorption Ratio in Wat <br />Sulfate <br />Sulfide as S <br />TDS (calculated) <br />TDS (ratio - measured /calculat <br />1. Negative (-)=. less than <br />2. U = not detected at MDL (Minimum Detection Level) <br />3. H - Exceeded hold time <br />4. B = Analyte concentration detected at a value between MDL and PQL <br />Flow (cfs) <br />Monthly Field Tests <br />Annual Test <br />8 <br />7 <br />5 <br />3 <br />15- Feb -11 17- Aug -11 <br />312 212 2 mgt <br />19(B) U 2 mgt <br />U U 2 mgt <br />331 212 2 mgt <br />0.01(B) U .01 mgt <br />1.5 0 % <br />43 17.3 0.1 meq/L <br />44.3 17.3 0.1 meq/L <br />21 8 1 mgt <br />2990 1380 1 umhos/cm <br />1940 769 1 mgt <br />0.72(H) 0.12 0.02 mgt <br />0.73(H) 0.13 0.02 mgt <br />0.01(HB) 0.01(B) 0.01 mgt <br />0.5 0.06(B) 0.05 mgt <br />8.4(H) 8.3(H) 0.1 su <br />0.24 0.18 0.03 mgt <br />0.08(H) 0.06 0.01 mgt <br />2910 1110 10 mgt <br />5(B) 52 5 mgt <br />1.2 0.67 0.03 mgt <br />1700 610 5 mgt <br />U U 0.02 mgt <br />2690 1060 10 mgt <br />1.08 1.05 <br />Flaw For SW -N3 <br />Tuttle Draw East <br />