Laserfiche WebLink
Matheson <br />• Mining <br />Consultants, Inc. <br />• <br />• <br />13246 County Road 45, Coaldale, Colorado <br />Martin and Angela Holmes <br />March 12, 2008 <br />The Holmes property was inspected in the order listed below. <br />No other significant pre existing damage was noted. Please refer to the DVD for additional <br />documentation. <br />2801Youngfield Street, Suite 171 <br />Golden, CO 80401 -2266 <br />303 -456 -5638 <br />Toll Free 888 -456 -5638 <br />Fax 303 -456 -5639 <br />www.mathesonmining.com <br />Residence Exterior <br />The paint on the redwood deck was very weathered. A minor hairline crack was noted in a <br />concrete pad at the base of the stairs leading up to the deck on the west side of the residence. <br />The siding paint on the north side of the residence was very weathered. A minor concrete crack <br />was noted in the pad on the northeast corner of the residence. Caulking around the windows on <br />the east and north sides of the residence was weathered and cracked. The steps leading to the <br />entrance on the south side had previously been replaced. Caulking around the windows and <br />slider door on the west side was cracked and weathered. <br />Residence Interior <br />Utility room- A hairline crack extending north/south in the concrete slab was visible in the utility <br />room on the northwest corner of the basement. <br />Basement- Minor hairline mortar separation cracking was noted in the foundation wall in the <br />southeast utility room on the east side of the residence. Minor efflorescence was noted on the <br />bottom of the south foundation wall near the pressure tank in the southeast utility room. <br />1 sl floor - The ceiling above the fireplace had previously been repaired. The ceiling in the sunroom <br />was in the process of being repaired as a leaky skylight had previously been removed. There was <br />mild water damage in the master bathroom around the tiolet. The shower in the master bathroom <br />was under construction. <br />Kitchen- A split ceiling wallboard seam was noted in the kitchen extending from the east wall <br />approximately two feet to the west. Mild water damage was noted around the skylight in the <br />southwest corner of the kitchen. Minor cracking was noted below the skylight in the southeast <br />corner of the kitchen, this was most likely caused by a leaky skylight. A minor hairline crack was <br />noted above the southeast frame of the kitchen/wall junction below the previously mentioned <br />skylight. <br />