/%/ <br />Mining <br />Consultants, Inc. <br />783 County Road 6, Coaldale, Colorado <br />Stephen Jones <br />March 12, 2008 <br />The Jones property was inspected in the order listed below. <br />2801Youngfield Street, Suite 171 <br />Golden, CO 80401 -2266 <br />303 -456 -5638 <br />Toll Free 888 -456 -5638 <br />Fax 303 -456 -5639 <br />www.mathesonmining.com <br />Residence Interior <br />Some loose /missing tile was noted in the bathroom. The caulking around the top of the bathtub was <br />cracked and weathered. The homeowner declared that the bathroom was under construction. <br />Residence Basement <br />A hairline crack was noted in the middle of the west basement wall near the top of the wall <br />extending down behind a shelf. Another vertical hairline crack was noted in the south basement <br />wall extending approximately 18 inches. A hairline crack was noted at the top of the basement <br />stairs on the west side of the porch floor. <br />Residence Exterior <br />The eaves just below the roofline on the north side of the residence were very weathered. A minor <br />foundation crack was noted on the east side of the north porch steps. Another minor foundation <br />crack was noted just under the window east of the north porch steps. This crack was identified <br />behind the wagon wheel. A minor foundation crack was noted on the east side of the residence just <br />to the south of the east porch window behind the rack of rock boxes. A minor foundation crack was <br />noted on the east side of the residence below the east window near the front porch. The roof seen <br />from the south side of the residence was very weathered. A minor concrete slab crack was noted on <br />the south porch near the south edge of the porch extending east/west opposite the front door. <br />Another crack was noted extending north/south from the east edge of the front door toward the <br />south edge of the porch. Two additional north/south cracks were noted on the east end of the south <br />porch extending to the east/west crack extending near the south edge of the porch. <br />Pumphouse <br />No significant pre- existing damage was noted. <br />Garage Exterior <br />A broken windowpane was noted on the south side of the garage. A cracked windowpane was <br />noted on the northeast corner of the garage. The tin roof on the northwest corner of the garage had a <br />few buckled panels. <br />Garage Interior <br />No pre- existing damage was noted. <br />