Laserfiche WebLink
ja(sC Matheson <br />Mining <br />Consultants, Inc. <br />• <br />• <br />266 Hayden Drive, Coaldale, Colorado <br />Susan Patterson <br />March 11, 2008 Exterior <br />March 17, 2008 Interior <br />The Patterson property was inspected in the order listed below. <br />2801Youngfield Street, Suite 171 <br />Golden, CO 80401 -2266 <br />303 -456 -5638 <br />Toll Free 888 -456 -5638 <br />Fax 303 -456 -5639 <br />www.mathesonmining.com <br />Residence Exterior <br />Two major vertical cracks were noted in the foundation on the east side of the residence. These <br />cracks were located under the deck, one located on the north side of a gas line and that ran through <br />the foundation while the other was located just south of the gas line. A major vertical crack was <br />also located in the foundation under the porch on the south side of the residence beneath the <br />fireplace. <br />Residence Crawlspace <br />A crack was noted on the inside of the crawlspace door on the west side of the door. A large <br />piece of foundation is missing near the east side of the crawlspace door where the crawlspace <br />entrance was constructed. A vertical crack was noted on the east foundation wall approximately <br />five feet from the north end of the east foundation. Another crack was noted about four feet <br />south of the previous crack. This crack was also a vertical crack running from the foundation <br />floor to the top of the foundation wall. The next two cracks were also visible from outside, this <br />lead the inspector to believe the foundation was cracked all the way through most likely from <br />differential settlement. The first crack just to the north of the gas line had split into two cracks <br />near the upper portion of the foundation. The second crack to the south of the gas line that runs <br />through the foundation also ran the height of the foundation wall. One additional vertical crack <br />running the height of the foundation was found between the last crack south of the gas line and <br />the southeast corner of the foundation. <br />One crack was noted on the south foundation wall, just west of the east most floor beam <br />connection to the foundation. A vertical foundation wall crack was noted midway in the west <br />foundation wall. An additional vertical wall crack was noted approximately ten feet north of the <br />previous crack on the west foundation wall. <br />A major vertical foundation crack was noted on the north wall approximately four feet east of the <br />spot where the electrical wires run through the foundation. This is mistakenly identified as the <br />south wall on the DVD. An additional vertical foundation crack was identified on the north <br />foundation wall approximately one foot west of the east most floor joist. <br />Residence Interior <br />No pre - existing structural or cosmetic damage was noted on the interior. <br />Please refer to the DVD for additional documentation. <br />