My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-10-06_PERMIT FILE - M2011014
DRMS
>
Day Forward
>
Permit File
>
Minerals
>
M2011014
>
2011-10-06_PERMIT FILE - M2011014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:43:50 PM
Creation date
10/6/2011 1:50:57 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2011014
IBM Index Class Name
PERMIT FILE
Doc Date
10/6/2011
Doc Name
Submittal of 110c application
From
Wasteline, Inc. for Dale and Ellen Schmidt
To
DRMS
Email Name
KAP
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Exhibit <br />Map <br />J. Details of slope 3u <br />Description <br />i i y m e a <br />Owner(s) <br />Potential Impact of proposed work in permit area <br />B <br />Structures N of River <br />Run Drive: <br />Riding Rings, Sheds, <br />and Fences /Gates <br />(Corrals) <br />Owner: <br />Daniel M. <br />Snow. <br />No significant impact. Excavation is minimal within 100 feet <br />of the ROW, and structures are located about 160 feet from <br />nearest excavation except for driveway (already built). <br />C <br />Structures N of River <br />Run Drive: <br />Building (house) and <br />driveway <br />Owner: <br />Mo's <br />Rentals LLC <br />No significant impact. Excavation is minimal within 100 feet of <br />the ROW, and structures are located about 250 feet from <br />nearest excavation except for driveway (already built). Only <br />one corner of the building is within 200 feet. <br />D/E <br />Structures E of Site: <br />Building (house), <br />shed /carport, patio, <br />driveway <br />Owner: <br />Matthew <br />G. Johnson <br />(both <br />properties) <br />No significant impact. Excavation has been underway within <br />200 feet of the structures and has apparently caused no <br />significant problems. Excavation will be no closer, and is at <br />approximately same elevation as structures, which are <br />located mostly in an excavated bench on the Johnson <br />property. Driveway and several structures are partially on <br />both lots, one structure on just a single lot; only portions are <br />within 200 feet.is minimal within 100 feet of the ROW, and <br />structures are located about 160 feet from nearest <br />excavation except for driveway (already built). <br />F <br />Structures W of Site: <br />driveway (gravel /semi- <br />improved) with culvert, <br />water well, and shed <br />Owner: <br />Robert S. <br />and Alice <br />M. Bennett <br />No significant impact. Though driveway is within 50 feet of <br />permit boundary and 75 feet of excavation, excavation has <br />been underway for some time and apparently has caused <br />no problems to the semi- improved road (really a trail). <br />Deeper excavation is not expected to result in any damage, <br />provided stabilization is provided as proposed. Water well <br />depth is significantly greater than depth of excavation <br />planned, and no blasting is planned; no impact expected. <br />Shed is portable and therefore not a permanent structure. <br />G <br />Strctures W of Site: <br />building (house) <br />Owner: <br />Daniel M. <br />Snow. <br />No significant impact. Only one end of the building <br />(apparently a modular unit) is within 200 feet of the Site and <br />is more than 200 feet from planned excavation. <br />P <br />River Run Drive (Gravel <br />road with drainage <br />features (ditches) in <br />Right of Way <br />Owner: <br />Archuleta <br />County <br />Road and <br />Bridge <br />No significant impact. Culverts for driveways are addressed <br />with landowners (above). Road is well below planned depth <br />of excavation, and there is minimal excavation proposed <br />within 100 feet of the ROW. Excavation within that distance <br />is limited to that needed for driveway improvements at the <br />entrance. Site drainage is designed to minimize storm water <br />discharge into ditches or onto road. Road maintenance is <br />assigned to the Aspen Springs Metropolitan Services District. <br />X1 <br />Utilities (electrical <br />power) lines and tower <br />La Plata <br />Electric <br />Association <br />LPEA will provide requirements to protect powerline tower <br />and access to powerline from construction on -site. Based on <br />existing excavation, no problem is expected but landowner <br />will have to indemnify LPEA for any damage. <br />Fencing <br />No fencing on -site or on permit boundary <br />Currently- existing road <br />(driveway) w/ <br />drainage <br />Ellen and <br />Dale <br />Schmidt <br />Existing culvert and road is to be improved as part of the <br />construction project. No significant negative impact. <br />Application for Reclamation Permit - Schmidt Site - M -201 1 -014 Exhibits P. 38 <br />6.3.12 EXHIBIT L - Permanent Man -Made Structures <br />REFER TO MAPS E 1 and E2. Letters identify specific properties and therefore owners of the <br />structures in those properties. Addresses of owners are provided in the letter to structure owners in <br />t b sures are designed are provided in Exh ibit for 6.5 <br />Prepared by Nathan A. Barton, PE, 26 SEP 2011, base on site inspections J u l y an Sep 20 11. <br />DALE AND ELLEN SCHMIDT, 472 Meadows Drive, Pagosa Springs, CO 81147, (970) 946 -6262 <br />©2011 WASTELINE, INC. 30 September 2011 <br />P 46 <br />
The URL can be used to link to this page
Your browser does not support the video tag.