Laserfiche WebLink
Minex Exploration <br />120 E. Lake St., Suite 401 <br />PO Box 2183 <br />Sandpoint, Idaho 83864 <br />208 - 265 -5858 <br />7. Measures to protect prevailing hydrological balance: <br />Should groundwater be encountered, the following measures will be taken. <br />Approximately 20 feet above the water table a grout plug would be installed using, for <br />example, a VK Grout Plug Packer and a bentonite mix such as Abantonite(Super Plug), <br />which has a 15% solids content, or Kwik Plug which has a solids content above 30% . <br />Cement would then be installed 20' on top of the grout plug. Once the cement has cured <br />then abandon with the Super Plug from that point to 20' from the collar. The top 20' of <br />the hole would then be cemented again. A hole marker would be placed in the cement at <br />the collar and then cover with Native soil. <br />8. Reclamation of Disturbed Areas <br />Reshaping of disturbed areas will occur with re- application of saved topsoil and re- <br />vegetation of the area with the recommended BLM seed mix. (See attachment). Topsoil <br />will be stockpiled separately from overburden and covered by plastic to protect its <br />integrity. <br />Gr.. _ory S <br />G logist <br />Minex Exploration <br />Claim Staking Geochem Sampling Geologic Mapping Prospecting Geophysical Survey <br />