company. In some areas, such as "T" joints, extrusion welds were used to provide: a complete <br />seal. Extrusion welds were also used at the inlet/outlet pipe boots. These welds were inspected <br />by TEC and found to be solid and continuous. <br />On TEC's final inspection of November 30, 1995, two locations were noted on the pond berm <br />where the liner had been ripped during liner anchor construction. While these rips are small and <br />not located within the pond, TEC recommends that these be repaired. <br />trust this submittal meets with your approval. If you should have any questions or concerns, <br />please feel free to contact me at (303) 850 -9852. <br />Respectfully, <br />Titan Environmental Corporation <br />.,l am'' <br />John F. Lupo, P.E. <br />Project Manager <br />• I <br />cc: Mitch Lapp - Henderson Mine <br />.Alan Sorenson - Division of Minerals and Geology <br />ptteh <br />•TII NFnviran <br />