Laserfiche WebLink
C- 2010 -089 PAR No. 2 <br />New Horizon North Mine <br />the NHN permit application. These data were not provided in Appendix 2.04.6 -4 as <br />indicated in WFC's response. If available, please include the laboratory reports as originally <br />requested. <br />9. Response accepted. <br />10. Response accepted. <br />2.04.7 — Hydrology Description <br />2.04.7(1) — Ground Water Information <br />9- Sep -2011 <br />Page 6 of 25 <br />1. In the second paragraph on page 2 of Section 2.04.7, WFC states that completion diagrams for <br />nine new monitoring wells are contained in Appendix 2.04.7 -1. Actually only "typical" <br />completion diagrams were provided, one for each of three monitoring zones. Please correct the <br />statement on page 2 as follows: "Typical completion diagrams one each for the overburden, <br />coal zone, and underburden well completion monitoring zones are provided in Figure 1 of <br />Appendix 2.04.7 -1." <br />DRMS: The statement on page 2 was not corrected as requested. Please correct the <br />statement on page 2 as follows: "Typical completion diagrams one each for the overburden, <br />coal zone, and underburden well completion monitoring zones are provided in Figure 1 of <br />Appendix 2.04.7 -1." <br />2. The application should contain the specific well completion information for each of the nine <br />new monitoring wells. Table 1 in Appendix 2.04.7 -1 is titled "Proposed Ground Water <br />Monitoring Hole Locations and Depths" and contains "Estimated Monitoring Hole Depths ". <br />This table should be replaced since the wells have been drilled and constructed. Please add a <br />well completion information table to Appendix 2.04.7 -1 that at a minimum contains the <br />following information for each monitoring well: well identification/location, formation <br />monitored, total depth, well casing type and diameter, ground elevation, casing stickup or <br />measuring point elevation, and slotted interval. <br />DRMS: The information was not incorporated as requested. Table 1 in Appendix 2.04.7 -1 has <br />not been changed. The application should contain the specific well completion information for <br />each of the nine new monitoring wells. Table 1 in Appendix 2.04.7 -1 is titled "Proposed <br />Ground Water Monitoring Hole Locations and Depths" and contains "Estimated Monitoring <br />Hole Depths ". This table should be replaced since the wells have been drilled and constructed. <br />Please add a well completion information table to Appendix 2.04.7 -1 that at a minimum <br />contains the following information for each monitoring well: well identification/location, <br />formation monitored, total depth, well casing type and diameter, ground elevation, casing <br />stickup or measuring point elevation, and slotted interval. <br />3. Response accepted. <br />4. Response is accepted; however, the reference to Appendix 2.04.7 -2 is incorrect, and should be <br />changed to Appendix 2.04.7 -1 in the second paragraph of revised page 5 (at 2 locations). <br />5. Response accepted. <br />6. Response accepted. <br />