CARRIER Fin <br />DIAMETER (In) <br />CASING PIPE <br />DIAMETER (In) <br />BORINGS AND <br />ENCASEMENTS <br />ENCASEMENTS ONLY <br />CASING SPACERS <br />(Y or N) <br />MIN STEEL CASING PIPE WALL 11aJCKNE S <br />(in) <br />CASING PIPE <br />MATERIALS <br />2' OR LESS <br />WATER SERVICES <br />q" <br />0.250 <br />0900 PVC <br />N <br />3" <br />6" <br />0.259 <br />0900 PVC, C151 DIP, <br />STEEL <br />Y <br />4" <br />8" <br />0.322 <br />C900 PVC, C151 DIP, <br />STEEL <br />Y <br />6' <br />12' <br />0.375 <br />C900 PVC, C151 DIP, <br />Y <br />5" <br />16" <br />0.375 <br />C905 PVC, C151 DIP, <br />STEEL <br />Y <br />10" <br />20" <br />0.375 <br />STEEL <br />Y <br />12' <br />24" <br />0.375 <br />STEEL <br />Y <br />15' <br />30" <br />0.500 <br />STEEL <br />Y <br />16' <br />30" <br />0.500 <br />STEEL <br />Y <br />PLASTIC SHAFT <br />'WITH FLARED END <br />ALL WIRES TO <br />BE CAD <br />WELDED TO <br />TOP OF PIPE <br />PIPE <br />BELL <br />CARRIER <br />PIPE <br />• FOUR TERMINAL <br />INSULATED BLOCK CAST IRON LOCKABLE COVER <br />NOTES: <br />CATHODIC TEST STATION DETAIL <br />45' <br />FOR CARRIER PIPFS 4 " -12" <br />as /U \ <br />Greeley <br />CASING PIPE <br />1" MIN GAP <br />CASING SPACER <br />RUNNER <br />SECTION A —A <br />DATE: JANUARY, 2008 <br />FINISHED GRADE <br />CONCRETE COLLAR <br />PER DETAIL 5 -33 <br />CASING PIPE <br />ANODE BAG <br />PIPE <br />BELL <br />CARRIER <br />PIPE <br />45' <br />CATHODIC PROTECTION NOTES: <br />1. INSTALL THE ANODES VERTICALLY OR <br />HORIZONTALLY IN SOIL WITH TOP OF <br />ANODES BELOW THE SPRINGUNE OF THE <br />PIPE. ANODES MUST BE PLACED IN NATIVE <br />SOIL, NOT SELECT BACKFIU. SUCH AS <br />SAND. BEDDING, OR CRUSHED ROCK. <br />2. INSTALL A 17 LB HIGH POTENTIAL <br />MAGNESIUM ANODE BAG ON EACH END OF <br />STEEL CASING PIPES WITH A CATHODIC <br />TEST STATION., <br />3. STATION TEST WIRES 70 BE THHN/THWH. <br />4. INSTALL A MINIMUM OF 2 FT SLACK AT <br />EACH END OF WIRES. <br />5. BE CAUTIOUS DURING BACKFILLING. DO <br />NOT DAMAGE OR STRESS WIRES OR <br />CONNECTIONS. <br />CASING PIPE <br />1" MIN GAP <br />7 5'� <br />FOR CARRIER PIPES 15" do 16 <br />1. CASING PIPE. CASING SPACERS, AND END SEALS 70 BE INSTALLED PER WATER AND <br />SEWER DEPARTMENT CONSTRUCTION SPECIFICATIONS <br />Z. RECOMMENDED CASING SPACER POSITIONING — PLACE ONE CASING SPACER 1 -2 FT ON <br />EITHER SIDE OF THE BELL JOINT AND ONE EVERY 6 -8 FT APART THERE AFTER FOR A <br />TOTAL OF 3 CASING SPACERS PER PIPE LENGTH UNLESS OTHERWISE SPECIFIED BY 1HE <br />MANUFACTURER OR CITY. <br />3. FOR 12' DIAMETER AND SMALLER CARRIER PIPES USE 8" CASING SPACER BANDWIDTH, <br />4. FOR CARRIER PIPES LARGER THAN 12' DIAMETER USE 12" CASIIIG SPACER BANDWIDTH. <br />5. CASING SPACERS TO BE IN THE 'CENTER RESTRAINED' P05111014. <br />6. POLYWRAP DIP CASING PIPES. <br />7. ALL BORINGS & ENCASEMENTS WILL REQUIRE END SEALS AS SHOWN. <br />RUNNER <br />CASING SPACER <br />END SEAL <br />TAINLESS <br />STEEL BAND <br />BORINGS AND ENCASEMENTS <br />Pap 224 <br />DETAIL NO. WS -3 <br />6' TO 8' TO 8' <br />1" MIN 11. A 1' TO 2' <br />CASING <br />SPACER <br />►A <br />ELEVATION VIEW <br />CASING PIPE <br />BANDWIDTH <br />SCALE: N.T.S. <br />