07/18/11 <br />01:26:48 PM <br />Project Description <br />Project File <br />Worksheet <br />Flow Element <br />Method <br />Solve For <br />Input Data <br />Mannings Coefficient <br />Channel Slope <br />Depth <br />Left Side Slope <br />Right Side Slope <br />Results <br />Discharge <br />Flow Area <br />Wetted Perimeter <br />Top Width <br />Critical Depth <br />Critical Slope <br />Velocity <br />Velocity Head <br />Specific Energy <br />Froude Number <br />Flow is subcritical. <br />c: \haestad \academic \fmw \may 1 .fm2 <br />May Day No. 1 Bench Perimeter Ditch <br />Triangular Channel <br />Manning's Formula <br />Discharge <br />0.035 <br />0.020000 ft/ft <br />1.00 ft <br />2.000000 H : V <br />2.000000 H : V <br />7.02 cfs <br />2.00 ft <br />4.47 ft <br />4.00 ft <br />0.95 ft <br />0.026564 ft/ft <br />3.51 ft/s <br />0.19 ft <br />1.19 ft <br />0.88 <br />May Day No. 1- Bench Perimeter Ditch <br />Worksheet for Triangular Channel <br />Academic Edition FlowMaster v5.17 <br />Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 (203) 755 -1666 Page 1 of 1 <br />