My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-08-08_REVISION - M1977493 (36)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M1977493
>
2011-08-08_REVISION - M1977493 (36)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:36:39 PM
Creation date
8/9/2011 7:40:13 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977493
IBM Index Class Name
REVISION
Doc Date
8/8/2011
Doc Name
EPP- Water Quality Monitoring Plan.
From
Climax Molybdenum
To
DRMS
Type & Sequence
TR18
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />Water Quality Monitoring Plan Climax Molybdenum Company <br />Version: R 1 Permit No. M -1977 -493 <br />• Sample preparation method references; <br />• Date and time of analysis; <br />• Analytical method references; <br />• Analytical result for each parameter requested, including results from QA/QC <br />samples; <br />• Unit of measurement; <br />• Method detection limit (in units of sample results); <br />• Laboratory quantification or reporting limit (defined); <br />• Calibration verification results; <br />• Theoretical concentrations for laboratory control samples, if used; <br />• Method blank results; <br />• Results of laboratory QC analyses [laboratory control sample /laboratory control <br />sample duplicate (LCS /LCSD); matrix spike /matrix pike duplicate samples <br />(MS /MSD); analytical duplicate, etc.] associated with each batch of samples <br />analyzed, as appropriate to the method protocol; <br />• Definition /explanation of any internal data qualifiers applied, and; <br />• A brief narrative describing sample analyses including description of any problems or <br />unusual circumstances during analysis. <br />6.3.4 Data Evaluation <br />All data shall be evaluated according to the following procedures to ensure that only data of <br />appropriate quality are used to evaluate site groundwater conditions. <br />6.3.4.1 Field Measurements <br />Field measurements including pH, specific conductance, and temperature will be collected <br />during monitoring activities. The field data will be reviewed in an attempt to identify any <br />transcriptional or computational errors. <br />6.3.4.2 Laboratory Data <br />Laboratory calculations and data review shall be performed by the laboratory in accordance with <br />the procedures described by the analytical method. The laboratory review shall include the <br />results of the QC analyses, instrument calibration, and maintenance records, calculations, and <br />the chain of custody record and analytical holding times. The laboratory will prepare a case <br />narrative to summarize the findings of their review, noting any problems associated with the <br />analysis of the field samples. <br />After receipt of the data from the laboratory, data evaluation shall be performed to: <br />• Ensure that the analytical laboratory was operating in control at the time the samples <br />were analyzed and to document that appropriate methods and holding times were <br />observed; <br />EPP — Appendix C <br />August, 2011 24 <br />
The URL can be used to link to this page
Your browser does not support the video tag.