My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-07-18_REPORT - C1996083
DRMS
>
Day Forward
>
Report
>
Coal
>
C1996083
>
2011-07-18_REPORT - C1996083
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:35:47 PM
Creation date
7/26/2011 9:20:48 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1996083
IBM Index Class Name
REPORT
Doc Date
7/18/2011
Doc Name
2nd Quarter 2011 Coal Mine Waste Bank
From
J.E. Stover & Associates, Inc
To
DRMS
Permit Index Doc Type
Waste Pile/Fill Report
Email Name
JJD
SB1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
readings. The previous movement in the B -axis of 13H05 -05 is interpreted to be due to <br />settlement of the coal refuse. <br />Vibrating Wire Piezometers <br />Five vibrating wire piezometers, designated VWP -01 through VWP -05, were installed in coal <br />refuse at CWDA No. 2 in June 2005. The piezometers were grouted in drilled boreholes as <br />described by BGI (2006). Piezometer locations are presented on the attached site plan. Since <br />installation two of the vibrating wire piezometers have stopped working correctly (VWP -01 and <br />VWP -04). Diagnostic tests indicate that shorts have developed, likely due to damaged cables. <br />Three additional vibrating wire piezometers, designated VWP -06 through VWP -08, were <br />installed at CWDA No. 2 in June 2009 to supplement the remaining piezometers. Completion <br />details of these piezometers are described by BGI (2009). During the June 15, 2011 site visit <br />we observed that VWP -05 and VWP -06, which had been buried by gob, were now uncovered <br />and able to be read. However, we had spurious readings on piezometers VWP -02, 03 and 07 <br />which could indicate damage to the wires leading to those piezometers. They will be re- <br />examined in our next quarterly instrumentation visit to determine their status. <br />Pore pressures measured to date are presented on the attached figure. Pore pressures have <br />remained relatively steady for piezometers VWP -02 and -03. Pore pressures at VWP -08 <br />decreased slightly between the March 2011 and June 2011 readings. This is most likely due to <br />continuing internal drainage and dewatering near the instruments at that site. Readings at <br />VWP -08 have generally decreased since a peak was recorded in January 2010. This is a good <br />indication that internal drainage is occurring and that waste material is dewatering due to <br />consolidation and trending towards equilibrium. All measured pore pressures are well below the <br />pore pressures at failure for similar confining pressures for the CU triaxial shear tests that have <br />been conducted as part of the on -going stability evaluation for this refuse bank. All other VWP <br />readings showed slight to significant decreases in pore pressures since the December 2010 <br />readings. <br />Pore pressures are anticipated to continue to decrease as drainage occurs. In any event, on- <br />going monitoring of all piezometers is recommended to monitor pore pressure responses to the <br />on -going refuse placement. Otherwise, the measured pore pressures are consistent with the <br />revised stability evaluation for the coal refuse performed by BGI (2008). <br />Closing <br />On -going monitoring of inclinometers and piezometers at CWDA No. 2 provides an indication of <br />the stability of the refuse as well as an indication of probable performance for other refuse piles <br />at Bowie. For these reasons, we recommend continued monitoring of this instrumentation on a <br />quarterly basis. We sincerely appreciate the opportunity to work with you on this project. If <br />you have any questions regarding this letter or the instrumentation monitoring at CWDA No. 2, <br />please don't hesitate to contact me at (970) 497 -8852 or dan(rbuckhorngeo.com. <br />Bowie Gob Pile 2 Instrumentation Monitoring 2nd Qtr 2011.doc <br />Project #05- 126 -GEO <br />Page 2 of 3 <br />
The URL can be used to link to this page