Laserfiche WebLink
ww*xtwib.cam <br />A~ &zdsm V= IM <br />-0711 • Billings, MT 800-735-4189 • Casper, WY OW235-0515 <br />12 <br />1RAp d C ty, Sl) 818-672-1225 • Cdlege Statimn, IX 868411111-n16 <br />QA/QC Summary Report <br />Prepared by Casper, WY Branch <br />Client: Cotter Corporation Report Date: 04/01/11 <br />Project: Schwartz SW 03/01/11 S25651-S25658 Work Order: C11030134 <br />Analyte Co unt Result Units RL %REC Low Limit High Limit RPD RPDLimit Qual <br />Method: E200.8 Batch: R143434 <br />Sample ID: LRB Method Blank Run: ICPMS4-C_110308A 03/08/11 10:59 <br />Uranium ND mg/L 8E-06 <br />Sample ID: LFB Laboratory Fortified Blank Run: ICPMS4-C_110308A 03/08/11 11:03 <br />Uranium 0.0543 mg/L 0.00030 109 85 115 <br />Sample ID: C11030148-002AMS Sample Matrix Spike Run: ICPMS4-C_110308A 03/09/11 04:13 <br />Uranium 42.4 mg/L 0.00030 70 130 A <br />Sample ID: C11030148-002AMSD Sample Matrix Spike Duplicate Run: ICPMS4-C_110308A 03/09/11 04:17 <br />Uranium 42.0 mg/L 0.00030 70 130 0.9 20 A <br />Qualifiers: <br />RL - Analyte reporting limit. A - The analyte level was greater than four times the spike level. In <br />accordance with the method % recovery is not calculated. <br />ND - Not detected at the reporting limit. MDC - Minimum detectable concentration <br />Page 23 of 43 <br />