Laserfiche WebLink
FLEXIBLE WALL PERMEABILITY TEST <br />ASTM D 5084-00 <br />Falling Head / Increasing Tailwater Pressure - Method C <br />CLIENT: Lyman Henn <br />PROJECT: Loveland Ready Mix Slurry Wall PROJECT NO. DV 108-159.03 <br />BORING NO. SB-93 LAB NO. : L28037 <br />DEPTH SAMPLE ID: <br />SAMPLE NO. Perm # 6 TEST STARTED 06/09/08 <br />SAMPLE TYPE Remolded, Slurry TEST FINISHED: 06/17/18 <br />CONF. PRESSURE. (psi) 10 SATURATED TEST: YES <br />MOISTUREIDENSITY BEFORE AFTER <br />DATA TEST TEST <br />Wt. Soil + Moisture (g) 1658.50 1539.80 <br />Wt. Wet Soil & Pan (g) 2732.20 1733.30 <br />Wt. Dry Soil & Pan (g) 2157.00 1481.60 <br />Wt. Moisture Lost (g) 575.20 251.70 <br />Wt. of Pan Only (g) 260.10 193.50 <br />Wt. of Dry Soil (g) 1896.90 1288.10 <br />Moisture Content % 30.3 19.5 <br />Wet Density (pct) 120.1 127.0 <br />Dry Density (pcf) 92.2 106.2 <br />Init. Diameter (in) 4.042 (cm) 10.267 <br />Init. Area (sq in) 12.832 (sq cm) 82.785 <br />Init. Height (in) 4.100 (cm) 10.414 <br />Height Change (in) 0.200 (cm) 0.508 <br />Consol. Height (in) 3.900 (cm) 9.906 <br />Area After Consol. (sq in) 11.846 (sq cm) 76.430 <br />Vol. Before Consol. (cu ft) 0.03045 Specific Gravity 2.60 <br />Vol. Before Consol. (cc) 862.1 Assumed? Yes <br />Change in Vol. (cc) 105.0 <br />Cell Exp. (cc) 0.0 Init. Saturation 103.6 <br />Vol. After Consol. (cc) 757.1 Init. Void Ratio 0.740 <br />Vol. After Consol. (cu ft) 0.02674 Final Saturation 99.8 <br />Effective Porosity % 43.23 Final Void Ratio 0.528 <br />Pressure Difference (psi): 3.73 <br />C = 0.04759 Buret Constant, a 0.319 <br />k, cm/s = C/t'log(hI/h2) Buret Stand 20 <br />Permeability Test Trials <br />Time Cap Pedestal Elevation Total Permeability <br /> Elevation Elevation Head Head k <br />min. cm cm cm cm cm/sec <br />0.0 39.3 2.3 37.0 299.3 <br />405.0 35.9 5.1 30.8 293.1 1.8E-08 <br />901.0 28.8 11.2 17.6 279.9 1.8E-08 <br />257.0 26.8 12.7 14.1 276.4 1.7E-08 <br />265.0 25.2 14.5 10.7 273.0 1.6E-08 <br /> Avg. of last 4 rdgs: 1.6E-08 <br />General Test Notes: <br />1) Tap water was used as the permeant. <br />2) Back pressure saturation continued until 'B' parameter a minimum of 0.95. <br />DVI08-159-3 Slurry Wall Pc=.xls Knight Nsold 7/172008