CM0001174 <br />3. Outlet Structure, including valve structure and <br />energy dissipater, all constructed of concrete, and 480, 360, <br />300, 18" and 120 steel piping and control valves and operators, <br />access ladders and platforms, 30 drain line, and all other <br />appurtenant.and auxiliary equipment listed herein and shown on <br />Woodward-Clevenger Drawing Numbers 11f6-6, -8, -11, and -12, and <br />Black and Veatch Drawing Numbers 11f6-30, - 31, -32 and -33, <br />that are necessary for normal access to the valve chamber and <br />outlet structure. The 300 supply canal and sluice gate shall <br />remain the property of Climax. <br />4. Piezometers and Monitoring Points, including nine <br />open wells and movement points as shown on.Woodward-Clevenger <br />Drawing Number 11f6-15A. <br />A-8