Laserfiche WebLink
r� <br />U <br />SEDCAD 4 for Windows <br />f nn ,Ar H+ 1002 _7!1!17 D-1n 1 Crh ... ok <br />Culvert Inputs: <br />Culvert Results: <br />Max. Entrance <br />Tailwater <br />Length (ft) Slope ( %) Manning's n Headwater <br />(ft) (ft) Loss Coef. <br />) (Ke) <br />71.00 5.00 0.0240 2.00 0.00 0.90 <br />Design Discharge = 7.51 cfs <br />Minimum pipe diameter: 1 - 18 inch pipe(s) required <br />Structure #5 (Cu/vertl <br />C3 -ID <br />Culvert Inputs: <br />Culvert Results: <br />Max. Tailwater Entrance <br />Length (ft) Slope ( %) Manning's n Headwater () ft Loss Coef. <br />(ft) (Ke) <br />260.00 3.00 0.0120 3.00 0.00 0.90 <br />Design Discharge = 0.88 cfs <br />Minimum pipe diameter: 1 - 6 inch pipe(s) required <br />Structure #4 (Erodible Channel) <br />D3 -1 <br />Triangular Erodible Channel Inputs: <br />Material: Graded silts to cobbles when colloidal <br />19 <br />Left Right <br />Freeboard Freeboard Freeboard <br />Limiting <br />Sideslope Sideslope Slope ( %) Manning's n <br />Mult. x <br />Velocity <br />Ratio Ratio <br />Depth (ft) % of Depth (VxD) <br />(fps) <br />2.0:1 2.0:1 2.0 0.0300 <br />0.30 <br />5.5 <br />Erodible Channel Results: <br />• Structure #3 (Cu/vert1 <br />Filename: MB -3.sc4 <br />Printed 09 -30 -2010 <br />w/o Freeboard w/ Freeboard <br />Design Discharge: <br />2.95 cfs <br />Depth: <br />0.68 ft 0.98 ft <br />Top Width: <br />2.72 ft 3.92 ft <br />Velocity: <br />3.18 fps <br />X- Section Area: <br />0.93 sq ft <br />Hydraulic Radius: <br />0.305 ft <br />Froude Number: <br />0.96 <br />• Structure #3 (Cu/vert1 <br />Filename: MB -3.sc4 <br />Printed 09 -30 -2010 <br />