My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2011-03-21_HYDROLOGY - C1981014
DRMS
>
Day Forward
>
Hydrology
>
Coal
>
C1981014
>
2011-03-21_HYDROLOGY - C1981014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:31:53 PM
Creation date
3/21/2011 9:46:56 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1981014
IBM Index Class Name
HYDROLOGY
Doc Date
3/21/2011
Doc Name
1st Quarter 2011 Pond Inspection Report
From
Energy Fuels Coal, Inc
To
DRMS
Permit Index Doc Type
Sediment Pond Inspect
Email Name
JHB
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENERGY FUELS COAL, INC. - SOUTHFIELD MINE - PERMIT NO. C-81-014 <br />PO BOX 459 -115 EAST MAIN ST <br />FLORENCE, CO 81226 <br />SEDIMENTATION POND INSPECTION FORM <br /> NPDES No <br />Pond . <br />Date of Inspection 423 -,.10' - <br />EMBANKMENT <br />1. Adequacy of the vegetative cover: E.VXIlca Moderate, Few, Poor <br />-- <br />2. Erosion forming gullies: Extensive, ------------ <br />Some. <br />Very Few, <br />Notu <br />3. Is wave action causing erosion: <br />On the upstream embankment? <br />Yes <br />No <br />At the principal spillway inlet? Yes Nom..., <br />4. Erosion of the dowTWream toe of the embanlaneru? Yes No?K, <br />The cause of the erasion is attributed to: - - <br />5. Is seepage occurring through the dam? Yes No X <br />Coats this seepage cause poterttfal instability? Yes No-_ <br />Explain: _ <br />PRINCIPAL SPILLWAY <br />1. Is the principal spilhvay system in wonting order° Yes _X_ No <br />2. Is the inlet fire of debris and restrictive material? Yes 'X No <br />3. Is the discharge outlet free of restrictive material? Yes X No <br />4. Is erosion occurring at the discharge outlet? Yes No k <br />Evaluate the severity: Extensive Moderate Just Staring None <br />EMERGENCY SPILLWAY <br />1 Is the overall etnetgency spillway system capat; a of passing design scoter discharge? <br />Yes No <br />2. Does it appear as if the emergency spillway has discharged water since the last inspecxion? <br />Yes No X <br />3. Is erosion occurring at any section of the emergency spillway? Yes No X <br />Describe the extent: <br />SEDIMENT STORAGE CAPACITY <br />i . Has the skzlga storage capacity of the reservir been surpassed? Yes ?vo <br />If yes, explain: <br />Pima add any special comments eancerW ag potentially dangetots probkms on the bark of this <br />sheet'. <br />Inspected bY:
The URL can be used to link to this page
Your browser does not support the video tag.