Laserfiche WebLink
C-1981-008 8-Feb-2011 <br />MR-79 PAR Page 2 of 2 <br />3. The IP section does not describe the potential season(s) that repair of the surface depressions <br />may be undertaken; nor are soil/ground conditions listed that might be prohibitive to the <br />proposed activities. Please expand the subsection 13.4 Reclaimed IP narrative to address <br />seasons of repair and conditions during which repairs will not be attempted. <br />4. With respect to repair of areas of differential settlement occurring on reclaimed Irrigated <br />Cropland (Prime Farmlands), the Division has determined that the issue is too complex to be <br />accomplished with a Minor Revision. Please remove the Irrigated Cropland section from <br />Subsection 13.4, and submit a Technical Revision application at a later date. <br />This concludes the Division's adequacy review of the MR-79 application. Please contact me <br />with any questions that may arise. <br />Sincerely, <br />Marcia L. Talvitie, P.E. <br />Environmental Protection Specialist <br />cc: Ross Gubka, Western Fuels <br />Sandy Brown, DRMS <br />