Laserfiche WebLink
samples were then taken according to the procedures outlined in the approved permit at the <br />time. The surrounding remediation test samples (4) around site #32 passed. See lab results in <br />Attachment 2.05.4(2)(d) -1. <br />Sample site #32 is located in Zone 3 on Map 2.04.5 -6, where it will be under at least 48 inches <br />of cover (Lift B Topsoil and Mixed Topsoil). This puts it under the spoil suitability <br />measurements, which have a threshold level of 8.0 mmhos /cm for EC. Therefore, no <br />remediation will be necessary <br />Sample site #32 was resampled in July 2010 by Walsh Environmental with the approved <br />saturation paste extract test for conductivity. The results of this test was a EC of 3.98 <br />mmhos /cm. Sample test results can be seen in Attachment 2.05.4(2)(d) -1 <br />There was some question about sample site #21 being elevated, so four more remediation test <br />samples were taken and those passed as well. The results of testing are shown within <br />Attachment 2.05.4(2)(d) -1. <br />Revised September 2010 (PR 06) 2.05.4(2)(d)48 <br />