Laserfiche WebLink
Accutest Laboratories <br />Report of Analysis <br />Client Sample ID: MW-2 <br />Lab Sample ID: D18515-1F Date Sampled: 10/26/10 <br />Matrix: AQ - Water Filtered Date Received: 10/27/10 <br />Percent Solids: n/a <br />Project: GCC <br />Page 1 of 1 <br />General Chemistry <br />Analyte Result RL Units <br />Alkalinity, Bicarbonate as CaC 314 5.0 mg/l <br />Alkalinity, Carbonate < 5.0 5.0 mg/l <br />Alkalinity, Total as CaCO3 314 5.0 mg/l <br />Cation Anion Balance 2.5 % <br />Chloride 47.9 1.0 mg/1 <br />Hardness, Total as CaCO3 a 921 1.8 mg/l <br />Nitrogen, Nitrate b < 0.090 0.090 mg/l <br />Nitrogen, Nitrite b <0.12 0.12 mg/l <br />Silica, Dissolved c 17.0 0.11 mg/l <br />Sulfate 950 50 mg/1 <br />(a) Calculated as: (Calcium * 2.497) + (Magnesium * 4.118) <br />(b) Elevated detection limit due to matrix interference. <br />(c) Calculated as: (Silicon * 2.139) <br />DF Analyzed By Method <br />1 11/02/10 Q SM20 2320B <br />1 11/02/10 Q SM20 2320B <br />1 11/02/10 Q SM20 2320B <br />1 11/05/10 MM SM201030E <br />2 10/27/10 13:37 JML EPA 300/SW846 9056 <br />1 10/29/10 23:39 JM SM20 2340E <br />2 10/27/10 13:37 JML EPA 300/SW846 9056 <br />2 10/27/10 13:37 JML EPA 300/SW846 9056 <br />1 11/10/10 14:03 cJ SW846 6010E <br />100 10/27/10 15:29 JML EPA 300/SW846 9056 <br />RL = Reporting Limit <br />11 of 64 <br />ACCUTEST. <br />D18515