Laserfiche WebLink
Require- <br /> ments <br />Requirements complied Comment <br /> with ? (yes <br /> / no) <br />Reclamation plan MCC's previously approved reclamation plan includes backfilling the <br />(2.05.4),backfilling/gr <br />yes <br />mudpit area and regrading to AOC, then seeding the regraded areas with a <br />, <br />ading (4.14), <br />seed mix previously approved by DRMS. <br />reve etation 4.15) <br /> None of the proposed new disturbance will be within 100 ft. of an ephemeral <br />Stream buffer zones <br />yes <br />stream having drainage areas larger than one mile. <br />(4.05.18) <br />Drillhole sealing The hole sealing and abandonment plan approved in PR-14 applies. A <br />(4.07) and DRMS mechanical packer will be placed at the lowest possible point in the/each <br />Guideline for yes hole, then the hole will be filled from bottom to top with cement grout <br />methane drainage placed with a tremmie tube. <br />wells <br /> The operator has sufficient bond to cover the $180,085 needed for this TR <br />Bond amount (3.02.2) yes (see attached summa of cost estimate and calculation of excess bond).