Laserfiche WebLink
\ www.energoab.com Helena, MT 877-472-0711 • Billings, MT 800-735-4489 • Casper, WY 888-235-0515 <br />Gillette, WY 866-686-7175 • Rapid City, SD 886-672-1225 • College Station, T% 888-690-2218 <br />QA/QC Summary Report <br />Client: Cotter Corporation Report Date: 11/29/10 <br />Project: Schwartzwalder Water Monitoring Program Work Order: C10100734 <br />Analyte Count Result Units RL %REC Low Limit High Limit RPD RPDLimit Qual <br />Method: A4500-F C Batch: R138764 <br />Sample ID: MBLK Method Blank Run: MANTECH_101020A 10/20/10 09:24 <br />Fluoride ND mg/L 0.05 <br />Sample ID: LCS Laboratory Control Sample Run: MANTECH_101020A 10/20/10 09:29 <br />Fluoride 1.04 mg/L 0.10 104 90 110 <br />Sample ID: 010100729-001AMS Sample Matrix Spike Run: MANTECH_101020A 10/20/10 10:36 <br />Fluoride 1.08 mg/L 0.10 100 80 120 <br />Sample ID: C10100729-001AMSD Sample Matrix Spike Duplicate Run: MANTECH_101020A 10/20/10 10:43 <br />Fluoride 1.08 mg/L 0.10 100 80 120 0.0 10 <br />Qualifiers: <br />RL - Analyte reporting limit. <br />MDC - Minimum detectable concentration <br />ND - Not detected at the reporting limit. <br />Page 10 of 29