Laserfiche WebLink
s www.ene elab.com Helena, W 8774724711 • Billings, MT 800-7354488 • Casper, WY 888-235-8513 <br />fiat <br />J <br />Gillette, WY 866-686-7175 • Rapid City, SO 888-672-1225 • Cdlege Station, T%888-680-2218 <br /> LABORATORY ANALYTICAL REPORT <br />Client: Cotter Corporation Report Date: 11/05/10 <br />Project: Schwartzwalder Water Monitoring Program Discharge Collection Date: 10/01/10 <br />Lab ID: C10100100_001 DateReceived: 10/04/10 <br />Client Sample ID: DIS-001A (S25415) Matri x: Aqueous <br /> MCL/ <br />Analyses Resul t Units Qualifiers RL QCL Method Analysis Date / By <br />MAJOR IONS <br />Chloride 27 mg/L 3 E300.0 10/14/10 23:16 / Ijl <br />Fluoride 0.3 mg/L 0.1 A4500-F C 10/05/10 10:47 / ja <br />Sulfate 828 mg/l_ 5 E300.0 10/14/10 23:16 / Ijl <br />NON-METALS <br />Cyanide, Weak Acid Dissociable ND mg/L 0.002 D2036 10/06/10 09:28 / eli-b <br />Sulfide ND mg/L 5 A4500-S F 10/04/10 15:46 / ja <br />PHYSICAL PROPERTIES <br />Oxygen Demand, Chemical (COD) 29 mg/L 5 HACH 8000 10/06/10 09:37 / ja <br />Solids, Total Dissolved TDS @ 180 C 1490 mg/L 10 A2540 C 10/06/10 17:22 / Ir <br />Solids, Total Suspended TSS @ 105 C ND mg/L 4 A2540 D 10/04/10 15:17 / Ir <br />METALS - DISSOLVED <br />Chromium ND mg/L 0.05 E200.7 10/15/10 12:18 / cp <br />Chromium, Hexavalent ND mg/L H 0.01 A3500 Cr-B 10/05/10 14:59 / ja <br />Chromium, Trivalent ND mg/L 0.05 Calculation 10/23/10 15:44 / sec <br />Iron ND mg/L 0.03 E200.7 10/15/10 12:18 / cp <br />Manganese ND mg/L 0.005 E200.7 10/15/10 12:18 / cp <br />- The sample was received past the EPA-recommended holdi ng time for Hexavalent Chromium analysis. <br />METALS-TOTAL <br />Antimony ND mg/L 0.001 E200.8 10/19/10 01:21 / s m I <br />Arsenic 0.0020 mg/L B 0.0005 E200.8 10/19/10 01:21 / smI <br />Boron ND mg/L D 0.2 E200.7 10/13/10 22:57 / cp <br />Iron ND mg/L 0.03 E200.7 10/13/10 22:57 / cp <br />Mercury ND mg/L 0.0001 E245.1 10/11/10 10:00 / rdw <br />Thallium 0.0002 mg/l_ 0.0002 E200.8 10/19/10 01:21 / sml <br />Uranium ND mg/L 0.0002 E200.8 10/19/10 01:21 / sml <br />METALS - POTENTIALLY DISSOLVED <br />Arsenic ND mg/L L 0.0008 E200.8 10/19/10 00:33 / sml <br />Cadmium ND mg/L 0.01 E200.8 10/19/10 00:33 / sml <br />Copper 0.002 mg/L 0.001 E200.8 10/19/10 00:33 / sml <br />Nickel ND mg/L 0.05 E200.8 10/19/10 00:33 / sml <br />Selenium 0.001 mg/L 0.001 E200.8 10/19/10 00:33 / sml <br />Silver ND mg/L L 0.0002 E200.8 10/19/10 00:33 / sml <br />Uranium ND mg/L 0.0002 E200.8 10/19/10 00:33 / sml <br />Zinc 0.017 mg/L 0.005 E200.8 10/19/10 00:33 / sml <br />Report RL - Analyte reporting limit. <br />Definitions: QCL - Quality control limit. <br />B - The analyte was detected in the method blank. <br />H - Analysis performed past recommended holding time. <br />MCL - Maximum contaminant level. <br />ND - Not detected at the reporting limit. <br />D - RL increased due to sample matrix. <br />L - Lowest available reporting limit for the analytical methoc <br />used. <br />Page 3 of 22