Laserfiche WebLink
Requirements for removing a pond, Require- <br />Section 4.05.2(2) ment met Comment <br /> (Yes / No) <br /> requirements of 434.81 - 434.82. Historical monitoring data in Carbon Junction's AHRs <br /> indicate drainage from the site meets the quality standards of pH greater than 6.0, net <br /> alkalinity greater than 0, and iron concentration less than 10 mg/l. The permit application <br /> contains the required adequate Sediment Control Plan and provides adequate designs and <br /> plans for implementing and maintaining the BMPs. The TR-15 submittal contains a <br /> watershed model in the form of a USLE calculation that is the same model used to acquire <br /> the mining and reclamation permit (Appendix 5-2), and which indicates the Sediment <br /> Control plan is designed to prevent an increase in the average annual sediment yield from <br /> re-mined, undisturbed conditions.