Laserfiche WebLink
Does the annulus pressure build back up after the test ? If Yes No psiq <br />MECHANICAL INTEGRITY PRESSURE TEST <br />Additional comments for mechanical integrity pressure test, such as volume of fluid added to annulus and <br />bled back at end of test, reason for failing test (casing head leak, tubing leak, other), etc.: <br />The long string of Well 29-27 took less than one barrel of water to fill up prior to the test. A <br />maximum pressure of 400 psi was reached with a slight drop to 388 psi over the 30 minute testing <br />time period. Water was removed from the well after the test to 5 feet below ground surface to <br />prevent freezing of the well head. <br />The short string of Well 29-27 took less than one barrel of water to fill up prior to the test. A <br />maximum pressure of 360 psi was reached with a drop to 340 psi over the 30 minute testing time <br />period. Water was removed from the well after the test to 5 feet below ground surface to prevent <br />freezing of the well head. <br />Signature of Witness: <br />OFFICE USE ONLY - COMPLIANCE FOLLOWUP <br />Staff <br />Do you agree with the reported test results? [ ] YES [ ] NO <br />If not, why? <br />Possible violation identified? [ ] YES [ ] NO <br />If YES, what <br />If YES - followup initiated? [ ] YES <br />[ ] NO -why not? <br />Date: <br />[ ] Data Entry <br />[ ] Compliance Staff <br />[ ] 2nd Data Entry <br />Page 2 of 2 <br />[ ] Hardcopy Filing