CYPRUS CLIMAX MINE STORM WATER MANAGEMENT PLAN <br /> BMP IDENTIFICATION <br /> (SECTION 2.3.1) <br /> Date of Identification: 7/10/96 By: W. W. Wheeler and Associates, Inc. <br /> Evaluation Deadline Date: <br /> Key Number: L4 (N1400, E6510) (Plate No. III) <br /> Description: Storks WWTP collection flume, evidence of overtopping, leakage through turnout gate, cracked concrete • <br /> Type of Character of Potential Pollutant: Stormwater contacting mine waste, boundary of process water system <br /> . BMP_ Detailed Control, Practice or Activity <br /> Good Housekeeping <br /> Preventive Maintain structures. Seal turnout leak. <br /> Maintenance <br /> Inspections During high runoff season when flows are maximum. <br /> Spill Prevention Regrade area to ensure collection and delivery to WWTP. <br /> or Containment <br /> Sediment and Consider sediment basin. <br /> Erosion Control <br /> Management <br /> of Runoff <br /> Other Specific Consider eliminating turnouts. <br /> Activities <br />