Laserfiche WebLink
<br />Client: Walsh Environmental <br />ClientPmject Name : New Horizon Mine <br />Client Project Number: 900882.0001.010 <br />Client Sample Number: TS-91 <br />Client Sample Location : New Horizon Mine. 0-18 <br />Sampling Data; 7/1512010 <br />Sampling Time: <br /> <br />Sample Mauix: Sail <br />Sampler: Edward <br />Analysis MI:1h d : •ICP-MS, EPA Mittbods 60201200.8 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />p Method: Key Laboratories, Inc. <br />2479A Riverside Parkway <br />Grand Junction, Colorado 81505.1319 <br />Phone (970) 243-5311 Fax (970) 243-6010 <br /> <br />Ivey tab 9: 10-1002 <br />Work Order r : 0716101002 <br />Data Received: 0711611D <br />'ry? (I <br />Analyst: V? ,1( t? <br />Sample Prep: Total, Open Vessel r <br />EPA Method 200.8 Open Vessel Microwave Digestion <br /> Wednesday, <br />Date Analyzed: July 21, 2010 <br />19:16:59 Wednesday, <br />July 21, 2010 <br />19:28:35 Wednesday, <br />July 21, 2010 <br />19:05:20 <br /> Key Lab Prep Batch Sample IDH Wt-0720A-i0. <br />1002-04_M <br />Sample Comments:, M <br />Sample Aliquot Intgl: 1D71.2 <br />Prep Au Spike Recovery: 0.988 <br />Prep/Digestion DP=>> 46.68 <br />Pass Audit =_» x Total DF=» 466.77 WI-D720A•10. <br />1002.04_MD <br />MD <br />1076.3 <br />0.998 <br />46.46 <br />464.55 Wi.0720AA0. <br />0000-01 LMB <br />LMB <br />1900 <br />0.951 <br />5o <br />500.00 <br />analysls loo Tm,• sy,aba RcaA Audit Analyte Reported Value Reported Value Units <br />Meblod Mesa m Lluor" Method Blank Blank DF MDL ppm PQL ppm Max QL ppm <br /> 1 cc--#Analytes Reported <br />1cP•MS' 7 1m Li Lifhlllm mg1K9 600.00 0,25 1 500 <br />ICPMa' 9 1. Be Beryllium mgfKg < < < <br />IcP-MS• 11 nM B Boron mg/Kg 500.00 0.5 2 Soo <br />ILP-Ma' V 1. Na Sodium mgfKg < < < <br />1w-Mr :4 ,o Mg Magnesium m9 9 <br />< <br />< <br />< <br />IcP•Ma' 27 m Al Aluminum mg/Kg < < < <br />ICP-MS• :e 10 Si Silicon mgfKg < < < <br />anMa' a+ +a P Phosphorus m9lK9 <br />< <br />c <br />< <br />Icp-Ms' a to K Potassium m91Kg < < < <br />ICP•Ms• as to <br />Ca <br />Calcium <br />mgfKg <br />< < <br />< <br />tc P•Ms• as w Ti Titanium mg/Kg < < c <br />IcP-Ms• Si 10 _ V Vanandium mg/Kg < < < <br />ICP-MS• 52 1. Cr 100 Chromium -g/Kg < < < <br />tcP-Ma• ss 1. Mu Manganese mgfKg < < < <br /> w 20 Fe Iron mgfKg < < < <br />1cP-Ma• 59 to Co Cobalt mg/Kg < c < <br />.cP•MS• as to Ni Nickel mg/Kg < < e <br />ICP-Ma- m 1a Cu Copper mg/Kg < < < <br />nPMS- as 10 Zn Zinc mgfKg < < < <br />IcP+us• 7s 1m As 100 Arsenic mgfKg 500.00 0.45 1.B 1000 <br />1c"S• e2 no Se 20 x Selenium 0.16 J < mg/Kg c 500.00 0.15 0.6 1000 <br />ICP-Mr ea 100 St. Strontium mg/Kg 500.00 0.025 0.1 1000 <br />IOP•Ma• 9a 1. Mo Molybdenum mg/Kg < < < <br />ICP-Ma• 107 10 Ag 100 Silver mgfKg < < < <br />ICP-Mr it 10 Cd 20 Cadmium mg/Kg < < < <br />tCAMS' Of 10 Sb Antimony mgfKg < < < <br />lep.- 137 100 Ba 2000 Barium mgfKg 500.00 0.03 0.12 1000 <br />cPMa• 2m to Hg 4 Mercury mgfKg < < < <br />ICP-Mb• 205 10 TI Thallium mg/Kg < < < <br />tcP•MS• 2os 1 Pb 100 Lead mgfKg < < < <br />IcP•MS' n2 too Th Thorium mg/Kg 500.00 D.oos 0.02 Soo <br />IcP-us• 2sa 100 U Uranium mgfKg 500.00 0.005 0.02 Soo <br /> <br />-lyptcany, an metals min ?- volmsf imcgralron time can ee repartee. Ayndaate at customers requesr. <br />Notes: LMB =laboratory method blank, M and MO = sample matrix replicates <br />Notes: LCS = spiked laboratory method blank, MS and MSD = spiked sample matrix replicates <br />Notes: Au Is spiked as sample prep surrogate and to facilitate analysis of Mercury, DF - Dilution Factor, <br />Notes: MDL - Method Detection Limit, PQL= Primary Quantitation Limit, MQL= Maximum Quantitation Limit, <br />Notes: < = less than MDL, J = Greater than MDL but less than PQL (4 x MDL), E =Estimated Value because it exceeds the MQL <br />Notes: n.a. = Not Applicable, Blank Space = Not Requested or Not Reported <br />Notes: RCRA TCLP Extract Limits: Ba = 100 ppm; ICr, As,Ag,Pb) - 5ppm; [Se, Cdi = 1 ppm; Hg = 0.2 ppm <br />Notes: "(Total RCRA limits) are 20 timas the TCLP extract limits because of TCLP sample size (100g) and extract volume (2000ml-). <br />-EPA SW846 Method 131 ].Revision 0, July 1997, Section 1.2: "If a total analysis of the waste demonstrates that individual analytes are not present in the waste, <br />or that they are present but at such low concentrations that the appropriate regulatory 1-1t, could not possibly be exceeded, the TCLP need not be run.' <br />Analyst! Reviewer <br />