Laserfiche WebLink
• <br />TRIAXIAL COMPRESSION TEST DATA <br />ASTM D 4767 <br />CLIENT Venture Resources JOB NO. 2789-01 <br />BORING NO. Slimes SAMPLED <br />DEPTH TEST STARTED 07/05/10 CAL <br />SAMPLE NO. TEST FINISHED 07/15110 CAL <br />SOIL DESCR. -100 tailings CELL NUMBER 8S <br />LOCATION Hukill Gulch Millsite SATURATED TEST Yes <br />TEST TYPE TX/CUpp, Stage 1 CONF. PRES. PSF 1000 <br />MOISTURE/DENSITY BEFORE AFTER <br />DATA TEST TEST <br />Wt. Soil + Moisture (g) 316.9 312.1 <br />M. Wet Soil & Pan (g) 325.1 3202 <br />Wt. Dry Soil & Pan (g) 252.5 252.5 <br />W. Lost Moisture (g) 72.6 67.8 <br />W. of Pan Only (g) 8.2 8.2 <br />Wt. of Dry Soil (g) 244.3 244.3 <br />Moisture Content % 29.7 27.7 <br />Wet Density PCF 102.8 104.0 <br />Dry Density PCF 79.2 81.4 <br />• <br />Init. Diameter (in) 1.938 <br />Init. Area (sq in) 2.950 <br />Init. Height (in) 3.983 <br />Vol. Bet Consol. (cu ft) 0.00680 <br />Vol. After Consol, (cu ft) 0.00662 <br />Notes & Comments: <br />Data entry by: MLM Date: 07/16/2010°1 <br />Data checked by: e-9_ Date: iL & (?) UI <br />FileName: VRTOSLIM