Laserfiche WebLink
TRI/ENVIRONMENTAL, INC. <br />. A Texas Research International Company <br />Proctor Compaction Test <br />130 <br />125 <br />120 <br />• <br />Cl <br />115 <br />110 <br />A <br />105 <br />A <br />100 <br />95 <br />90 <br />0 <br />-? <br />f <br />Project: Venture Resources, Inc. (Huldll <br /> Gulch Millsite <br /> Sample No.: Sub2rade <br />1 k - TRI Log No.: E2337-21-10 <br /> <br /> Test Method: ASTM D 698 - Method C <br />I Maximum Dry Density (pcf): 118.2 <br /> Optimum Moisture Content (%): 11.4 <br /> t <br /> ; 2.80 <br />- -- -- -? !? - - X2.20- -:- <br /> 2.60- , <br /> <br /> <br /> <br />5 10 15 20 25 30 35 40 <br />Moisture Content (%) <br />Chong-Wei Chen, 04/22/1.0 <br />• <br />Quality Review/Date <br />Tested by: Larry Miller <br />The testing herein is based upon accepted industry practice as well as the test method listed. Test results reported herein do not apply <br />to samples other than those tested. TRI neither accepts responsibility for nor makes claim as to the final use and purpose of the material. <br />TRI observes and maintains client confidentiality. TRI limits reproduction of this report, except in full, without prior approval of TRI. <br />9063 Bee Caves Road 0 Austin, TX 78733-6201 0 (512) 263-2101 0 (512) 263-2558 0 1-800-880-TEST