Laserfiche WebLink
2.5 Sample Adeauacv Determination <br />Sampling within each managerial unit was conducted to a minimum of 30 or 45 samples per unit. <br />From these preliminary efforts, sample means and standard deviations for total non - overlapping <br />vegetation ground cover, production, and woody plant density were calculated. For non - monitoring <br />applications, the typical procedure is that sampling must continue until an adequate sample, n m i n , has <br />been collected in accordance with the Cochran formula (below) for determining sample adequacy, <br />whereby the population is estimated to within 10% of the true mean (u) with 90% confidence. <br />When the inequality (n <_ n) is true, sampling is deemed adequate; and n min is determined as <br />follows: <br />nmin = (r2 / (0.1X )2 <br />where: n = the number of actual samples collected (initial size = 30 or 45) <br />t = the value from the one - tailed t distribution for 90% confidence with n -1 <br />degrees of freedom; <br />S 2 = the variance of the estimate as calculated from the initial samples; <br />x = the mean of the estimate as calculated from the initial samples. <br />If the initial samples do not provide a suitable estimate of the mean (i.e., the inequality is false), <br />additional samples would be collected until the inequality (n 5 n) becomes true. <br />CEDAR CREEK ASSOCIATES, Inc. Page 14 Rio Tinto Energy America - Colowyo Mine <br />2009 Phase III Bond Release Evaluation — Year 2 <br />